[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Nikon 1 J5 / prf-solomatov-pred-nikon-1-j5-c3a5810cb8d3@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Nikon 1 J5 / prf-solomatov-pred-nikon-1-j5-c3a5810cb8d3@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27016026 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27016026; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.010670011200018833,
        0.02128669479367543,
        0.024087846969054593,
        0.0016225834251121908,
        0.00700037525874457,
        0.019561751976400973,
        0.030245943648410763,
        0.039795416246638196,
        0.05605457294126087,
        0.04558836669760386,
        0.030648408466885546,
        0.01684590324276413,
        0.011232259696522353,
        6.035317703647457e-8,
        0.000007298638223105057,
        0.000038521028222285544,
        0.04643494938892938,
        0.2364843000965427,
        0.49465228527689453,
        0.6315331129752392,
        0.6206562726879225,
        0.5691818256319415,
        0.49278369068789024,
        0.4210057023190606,
        0.35143458923233195,
        0.2793264819925773,
        0.21528560862356294,
        0.1462505255214072,
        0.08608843876593841,
        0.03481563128492696,
        0.01938216227656873
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Nikon 1 J5 / prf-solomatov-pred-nikon-1-j5-c3a5810cb8d3@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Nikon 1 J5 / prf-solomatov-pred-nikon-1-j5-c3a5810cb8d3@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27016026 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27016026; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.016718349693622594,
        0.028389834241349932,
        0.05485380418274694,
        0.08949611241860665,
        0.12417169719928461,
        0.147628866658627,
        0.18560894929550334,
        0.2632445127199685,
        0.3609319520198863,
        0.4708342744414001,
        0.6176775222232908,
        0.8030496047049999,
        0.9414081849047673,
        1,
        0.9907689606161915,
        0.9336468657529423,
        0.8389370442566202,
        0.7002851936846671,
        0.5502231527316416,
        0.40222233277388764,
        0.28109948517224553,
        0.18813647869601546,
        0.13915230907758233,
        0.09861644343990489,
        0.0687490084589051,
        0.04184021365688648,
        0.03244474594449976,
        0.016140079225567816,
        0.004864628868805501,
        0.006906493205181251,
        0.00002579425449175982
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Nikon 1 J5 / prf-solomatov-pred-nikon-1-j5-c3a5810cb8d3@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Nikon 1 J5 / prf-solomatov-pred-nikon-1-j5-c3a5810cb8d3@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27016026 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27016026; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04699849267246042,
        0.1188542978156743,
        0.28394674331450526,
        0.47331117463390066,
        0.6127247212450861,
        0.722094137753643,
        0.8158706613622596,
        0.8590344116488488,
        0.8507569173941424,
        0.7493043203319394,
        0.5858522641338886,
        0.401112361973593,
        0.2301894179402996,
        0.11051171996947294,
        0.06769875036395065,
        0.051144850097493984,
        0.06288719887965757,
        0.07225363197385137,
        0.057958076439517794,
        0.04482941717630861,
        0.03943731768691665,
        0.030487215255123018,
        0.00726618785457195,
        0.000014337197484189571,
        0.000023978195756844477,
        0.000022750567755598107,
        0.000017315015169144416,
        0.00003142980207377651,
        0.000005942909219883043,
        0.000020758147774954024,
        0.001001695327062537
      ],
      "range": 1
    }
  }
]
