[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Nikon 1 J5 / prf-solomatov-pred-nikon-1-j5-c3a5810cb8d3@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Nikon 1 J5 / prf-solomatov-pred-nikon-1-j5-c3a5810cb8d3@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000509736339623 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27016026; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.014137764840024953,
        0.027516946928409697,
        0.030396568794283173,
        0.001999928407696421,
        0.00843227019803323,
        0.023039396772205588,
        0.034848587247081966,
        0.04487568215046435,
        0.06189359095597554,
        0.049309866019857235,
        0.03248731297489867,
        0.017506526899343115,
        0.011448264690686244,
        6.035317703647457e-8,
        0.000007163478256010518,
        0.00003712026355965697,
        0.04394736281452244,
        0.21988891061608354,
        0.4520098468909553,
        0.5673094065709775,
        0.5482463742076648,
        0.49453502882775247,
        0.42125057429771257,
        0.3541794003636541,
        0.2910317692080249,
        0.22775851608625536,
        0.17288086753104293,
        0.11569071421842657,
        0.06709834197933434,
        0.026742441421755487,
        0.014675065723687753
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Nikon 1 J5 / prf-solomatov-pred-nikon-1-j5-c3a5810cb8d3@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Nikon 1 J5 / prf-solomatov-pred-nikon-1-j5-c3a5810cb8d3@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000509736339623 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27016026; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.022151813344049934,
        0.036699054019306,
        0.0692202767067997,
        0.1103091618182826,
        0.14957045344459283,
        0.17387399850904955,
        0.2138537894056886,
        0.29685019519485806,
        0.3985290303552911,
        0.5092697254162082,
        0.6547381735566882,
        0.8345417460659802,
        0.9595121884606281,
        1,
        0.972421387271447,
        0.8996960706346534,
        0.7939939883143011,
        0.6511423730752167,
        0.5027901223237414,
        0.36131836672908546,
        0.24830454523548356,
        0.16346284214571835,
        0.11895278034051392,
        0.08296303971928506,
        0.05693277263003078,
        0.034115866520230506,
        0.026054114167552836,
        0.01276752535753872,
        0.0037915489712748757,
        0.0053049875344145835,
        0.000019529935543761003
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Nikon 1 J5 / prf-solomatov-pred-nikon-1-j5-c3a5810cb8d3@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Nikon 1 J5 / prf-solomatov-pred-nikon-1-j5-c3a5810cb8d3@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000509736339623 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27016026; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06227300279101005,
        0.15364092156660336,
        0.35831374751592326,
        0.5833835408278311,
        0.7380547778633992,
        0.8504664289098461,
        0.9400248924391251,
        0.9686983790933824,
        0.9393774296226987,
        0.8104720199508731,
        0.6210033999819218,
        0.416842258521577,
        0.23461613751607455,
        0.11051171996947293,
        0.06644506980165527,
        0.04928503736667602,
        0.05951824179681877,
        0.06718320165989689,
        0.052961690539559354,
        0.04027049339566705,
        0.0348362972901097,
        0.026488891942975736,
        0.006211418649876022,
        0.000012061451851778528,
        0.00001985694336113683,
        0.000018550462939179992,
        0.000013904481878252334,
        0.000024862380744927686,
        0.0000046319733625559005,
        0.0000159446642329357,
        0.0007584264619187778
      ],
      "range": 1
    }
  }
]
