    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Nikon D2Hs / prf-solomatov-pred-nikon-d2hs-fd23399945d3@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Nikon D2Hs / prf-solomatov-pred-nikon-d2hs-fd23399945d3@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.28677726 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28677726; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.007985852853186478,
        0.014777092158562363,
        0.022756136940564956,
        0.0116471375729024,
        0.03554449540385455,
        0.041274257589322114,
        0.04118572720863572,
        0.02944132669375529,
        0.023286155952532642,
        0.021107055350204545,
        0.026555245349648714,
        0.04560286091024093,
        0.07403487640547232,
        0.09740750364934794,
        0.10782502420170972,
        0.13005193647501898,
        0.17600755373700133,
        0.29597542008735284,
        0.448119945075143,
        0.5305054522105414,
        0.5086104804823088,
        0.45472691942171434,
        0.38168782978120375,
        0.31405251587939714,
        0.25094702418176396,
        0.19164169432401998,
        0.14035234174425126,
        0.08960144538656936,
        0.048508500987839834,
        0.018557891933272536,
        0.007893670858003177
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Nikon D2Hs / prf-solomatov-pred-nikon-d2hs-fd23399945d3@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Nikon D2Hs / prf-solomatov-pred-nikon-d2hs-fd23399945d3@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.28677726 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28677726; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01608582354123894,
        0.023490288595406764,
        0.04351481180899769,
        0.06760022046378433,
        0.08533305604495978,
        0.10044527937814875,
        0.14744469279049532,
        0.2526446831941975,
        0.37672953566820466,
        0.5049936316428995,
        0.6615959368605446,
        0.8377857086716012,
        0.9587119982944254,
        1,
        0.9742617667802532,
        0.898912626475335,
        0.790267296646882,
        0.6430474996518204,
        0.4788845879899962,
        0.3207884404781607,
        0.18827153868476185,
        0.09537601412329556,
        0.05279924914548664,
        0.03486692424636459,
        0.020155217327901105,
        0.010905306090169074,
        0.0181986141439527,
        0.009726656151188558,
        0.0013417189005850744,
        0.008341181933323446,
        0.000042337561911289625
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Nikon D2Hs / prf-solomatov-pred-nikon-d2hs-fd23399945d3@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Nikon D2Hs / prf-solomatov-pred-nikon-d2hs-fd23399945d3@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.28677726 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28677726; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.040295583408531066,
        0.10515780086607984,
        0.2644009849316505,
        0.45465644660946963,
        0.5891659610667875,
        0.6898240467183486,
        0.769026944465541,
        0.7965082029167865,
        0.7778806101990096,
        0.6793205291102928,
        0.5321278611839726,
        0.37512848822113726,
        0.23235820720234235,
        0.13213769111260776,
        0.09439509952776591,
        0.0703709213206096,
        0.06370267991262628,
        0.050138767976233546,
        0.03177170846809821,
        0.017396660042013096,
        0.008714401204614341,
        0.0008507033646949553,
        0.00002505162368871228,
        0.00004343207337987678,
        0.00004593192640169587,
        0.00012105956378828644,
        0.00001331840816109339,
        0.000028138496755286662,
        0.00014858799125146813,
        0.00003222075906576414,
        0.006259074377096706
      ],
      "range": 1
    }
  }
]