[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus AIR A01 / prf-solomatov-pred-olympus-air-a01-9e2519287402@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus AIR A01 / prf-solomatov-pred-olympus-air-a01-9e2519287402@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00052472490566 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2781042; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.015380502074402329,
        0.025234744685361923,
        0.028724062436892014,
        0.00237126377911254,
        0.00883946901589731,
        0.01836952172762743,
        0.02748358122446629,
        0.02611013938492088,
        0.03597793538357205,
        0.03270609779811058,
        0.025870965630867854,
        0.03384768913883329,
        0.0468814958012694,
        0.042189521050023694,
        0.02325934602396698,
        0.024218721864290107,
        0.07468141116582509,
        0.2721538337447846,
        0.5370688731430334,
        0.6464797976771028,
        0.6077045258575742,
        0.5405733092305619,
        0.45557973269290497,
        0.3816265744084525,
        0.3129559200517288,
        0.24570181469889563,
        0.18334998394868038,
        0.11943553246932345,
        0.06495334857984038,
        0.025239510945897256,
        0.017768250780000546
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus AIR A01 / prf-solomatov-pred-olympus-air-a01-9e2519287402@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus AIR A01 / prf-solomatov-pred-olympus-air-a01-9e2519287402@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00052472490566 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2781042; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.02081820041732559,
        0.03359930416325265,
        0.05903047328166581,
        0.09519934965651071,
        0.12255699776623946,
        0.14324207105745895,
        0.1951106416697176,
        0.30127709593987023,
        0.43277748502180113,
        0.5639620989806948,
        0.7109704837251648,
        0.8769190292632733,
        0.9790040131886371,
        1,
        0.9601873253369168,
        0.8783153619791039,
        0.7667677644360844,
        0.6196429819811196,
        0.46305734970239015,
        0.32308128465298197,
        0.21034650501502675,
        0.12947945239442685,
        0.08850905982072024,
        0.05949032572843001,
        0.039973472454299504,
        0.02376505043239742,
        0.01908694969640004,
        0.008671838903891138,
        0.004750400363054779,
        0.00578440515503161,
        0.0003135947692576071
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus AIR A01 / prf-solomatov-pred-olympus-air-a01-9e2519287402@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus AIR A01 / prf-solomatov-pred-olympus-air-a01-9e2519287402@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00052472490566 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2781042; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.060715366578426355,
        0.1407446476326008,
        0.3286276803545474,
        0.5540304610269636,
        0.6993768988549812,
        0.7869757107028389,
        0.8371173568255602,
        0.8221762623582372,
        0.7440712345109015,
        0.6144334822732498,
        0.4545837398356443,
        0.3114256299842811,
        0.19867191512832516,
        0.130700435304465,
        0.11092180084006349,
        0.09936347318085026,
        0.09659905904230964,
        0.08023065486864023,
        0.05236077309797228,
        0.029711000043527152,
        0.01652494937149457,
        0.005960214735410943,
        0.00008235992068742115,
        0.0000014411606855409215,
        0.000016932936962117078,
        0.0000468086737605213,
        0.00002480469147459074,
        0.000014704310443845557,
        0.000021177406536618924,
        0.0004260374557345824,
        0.0013873728459641078
      ],
      "range": 1
    }
  }
]
