    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E 410 / prf-solomatov-pred-olympus-e-410-b6c0f91ecbb9@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E 410 / prf-solomatov-pred-olympus-e-410-b6c0f91ecbb9@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000531875132075 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28189382; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.011032345086529389,
        0.021946309645864567,
        0.025334875920234617,
        0.0013205479299443891,
        0.016509573509564054,
        0.024231169436618207,
        0.03208834231025123,
        0.033161574884034685,
        0.040536856365516155,
        0.038664468683670336,
        0.036289295806484864,
        0.043621380380100584,
        0.05926987590848649,
        0.06529863265537357,
        0.061338391000738686,
        0.07266822509140627,
        0.11962242455079614,
        0.26708316702553575,
        0.4688131418198281,
        0.5615792108640438,
        0.5330025781811509,
        0.47353598843892564,
        0.3962760094013984,
        0.3288939522385718,
        0.2670543285145449,
        0.20761816411801925,
        0.15588572848049126,
        0.10124246183698823,
        0.05798091599545823,
        0.022944810120041095,
        0.013427326126857672
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E 410 / prf-solomatov-pred-olympus-e-410-b6c0f91ecbb9@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E 410 / prf-solomatov-pred-olympus-e-410-b6c0f91ecbb9@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000531875132075 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28189382; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.020701697797064156,
        0.032875337799521676,
        0.059309960091660445,
        0.09526347701365168,
        0.12656706610311638,
        0.14762017903683655,
        0.19967130994339577,
        0.30403860740219524,
        0.42773722241705514,
        0.5500108277127398,
        0.7031784293816729,
        0.8747073701749981,
        0.9797627143112578,
        1,
        0.9549010989971985,
        0.8682765924224427,
        0.751847924766242,
        0.5997632171785989,
        0.4435924503234146,
        0.30190140086271616,
        0.1877952373462225,
        0.10644243085081803,
        0.06843393774660352,
        0.04396779688970202,
        0.02775412648058407,
        0.017721040234772955,
        0.014770822810754296,
        0.007049199715768495,
        0.0045172209699382545,
        0.0045317441700648805,
        0.00014469444786997153
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E 410 / prf-solomatov-pred-olympus-e-410-b6c0f91ecbb9@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E 410 / prf-solomatov-pred-olympus-e-410-b6c0f91ecbb9@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000531875132075 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28189382; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06085492260880355,
        0.14123695555592267,
        0.33390150065655755,
        0.5562985200729867,
        0.7108750291155724,
        0.8050614321535833,
        0.8731051834864012,
        0.8783763801259967,
        0.8229002265226435,
        0.6956207294430135,
        0.5242636535983655,
        0.3558687404593214,
        0.21477209527113653,
        0.12157486460682251,
        0.08865402333508515,
        0.07072469304544912,
        0.06876112443938744,
        0.060543045555113306,
        0.045871260540826915,
        0.03215587163821265,
        0.021326222358002266,
        0.01324222128836416,
        0.005425456671776674,
        0.00006552873533662257,
        0.0001055168069354979,
        0.00003350053222167126,
        0.0000515796674253039,
        0.00007724602322663256,
        0.0002417937327274086,
        0.00003492898398637359,
        0.000025786981677812485
      ],
      "range": 1
    }
  }
]