[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E 620 / prf-solomatov-pred-olympus-e-620-8e60ccf54cb7@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E 620 / prf-solomatov-pred-olympus-e-620-8e60ccf54cb7@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26640236 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26640236; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.011693216982011721,
        0.02211626278385822,
        0.025698503571815207,
        0.0008451167624791312,
        0.01335629534212835,
        0.03198908785943187,
        0.05644648568428598,
        0.0779769293335089,
        0.1104587324226407,
        0.10659887547542747,
        0.09396699413623813,
        0.07817557246865231,
        0.06380791071070091,
        0.03526608022541542,
        0.002469222269652566,
        0.00028162021537647035,
        0.04405127642262628,
        0.2544889617344231,
        0.565289286476291,
        0.7227132672548396,
        0.7081189520993733,
        0.6469233230516426,
        0.5598576153754794,
        0.4852053487814448,
        0.4120435344491693,
        0.3367583155044122,
        0.26771868687649764,
        0.18578662366204263,
        0.10686085889028911,
        0.0439041606087874,
        0.02980233358293072
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E 620 / prf-solomatov-pred-olympus-e-620-8e60ccf54cb7@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E 620 / prf-solomatov-pred-olympus-e-620-8e60ccf54cb7@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26640236 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26640236; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01880363597379543,
        0.03127608929590564,
        0.06351121664237509,
        0.10368247488498225,
        0.15127335959035798,
        0.1904079828722238,
        0.24592004365126496,
        0.34103335270753604,
        0.45913283200644317,
        0.5763894133670587,
        0.7110468540894307,
        0.8655665437798674,
        0.9693091682821428,
        1,
        0.9763110582053401,
        0.9139610474922218,
        0.8206894263249019,
        0.6929509558398806,
        0.5548363385369409,
        0.41726586055769177,
        0.3005705354862472,
        0.20910664980595517,
        0.15322398044822125,
        0.1089099210682668,
        0.07765923319898517,
        0.0518349049160075,
        0.0380990318554235,
        0.022850574597011827,
        0.012260299420770898,
        0.008464714802076077,
        0.003009123267526609
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E 620 / prf-solomatov-pred-olympus-e-620-8e60ccf54cb7@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E 620 / prf-solomatov-pred-olympus-e-620-8e60ccf54cb7@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26640236 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26640236; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.0489195703821843,
        0.11847336112187594,
        0.27543795032446405,
        0.45844915187688273,
        0.5858410188258092,
        0.673088256425356,
        0.7420016849700581,
        0.7601453680815741,
        0.7287522903325631,
        0.6330177029963248,
        0.5009152696695329,
        0.3663914238597586,
        0.24373770562693212,
        0.15586921226974115,
        0.1115246464032826,
        0.08024624481554893,
        0.06635916063206046,
        0.060362333126478304,
        0.05575926391943375,
        0.03995458598790191,
        0.02047407650592885,
        0.008704227319908128,
        0.005292512799060789,
        0.0014305396919156422,
        0.000021658554376169938,
        0.000012373088586752759,
        0.000011508244146185493,
        0.000028256771824393746,
        0.000025173716178790606,
        0.00005804930181549443,
        0.0013455580123239148
      ],
      "range": 1
    }
  }
]
