[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M1 Mark III / prf-solomatov-pred-olympus-e-m1-mark-iii-9cc4ad06c4de@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M1 Mark III / prf-solomatov-pred-olympus-e-m1-mark-iii-9cc4ad06c4de@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000510446037736 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2705364; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.017924223764343723,
        0.03251920628795238,
        0.0360546515930503,
        0.00033008144835292415,
        0.01174105321199594,
        0.0317703261701157,
        0.058423677681755985,
        0.07615761989569217,
        0.10709168248708861,
        0.1025351463512745,
        0.08585669935727688,
        0.07356293333119959,
        0.05990930489603958,
        0.026481522264656436,
        0.00007752732657540107,
        0.00004953658163425092,
        0.03251277633725337,
        0.27333849675953714,
        0.576192960763671,
        0.6876919090733465,
        0.6417970607035997,
        0.5665273466064419,
        0.4755588783449615,
        0.3970996063247236,
        0.3275423358002842,
        0.257939900139131,
        0.19225977903471947,
        0.12403386030410737,
        0.06600686777214801,
        0.026136678085098525,
        0.019266812303261223
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M1 Mark III / prf-solomatov-pred-olympus-e-m1-mark-iii-9cc4ad06c4de@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M1 Mark III / prf-solomatov-pred-olympus-e-m1-mark-iii-9cc4ad06c4de@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000510446037736 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2705364; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.023718393532256656,
        0.039737594302715167,
        0.07381412216970575,
        0.11389610194912342,
        0.15748672989862159,
        0.19412185815537822,
        0.2517828510643878,
        0.35314721325736886,
        0.47746734127089735,
        0.5925487132758687,
        0.727379649466763,
        0.8830408555656357,
        0.9807094065999706,
        1,
        0.9644606377880718,
        0.8870533240964651,
        0.7827288134134366,
        0.6410234098407278,
        0.49007851846719436,
        0.3544706437448224,
        0.24542958002447482,
        0.16374088359395583,
        0.1166336361105495,
        0.08143817480723715,
        0.05535777371362966,
        0.034202217008648235,
        0.024018263178431646,
        0.011989870891542456,
        0.005773577973241309,
        0.006533108357847702,
        0.002758062073294811
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M1 Mark III / prf-solomatov-pred-olympus-e-m1-mark-iii-9cc4ad06c4de@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M1 Mark III / prf-solomatov-pred-olympus-e-m1-mark-iii-9cc4ad06c4de@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000510446037736 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2705364; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.059631202908370186,
        0.13731573562924548,
        0.319530721013442,
        0.5410589919155615,
        0.6816533913567806,
        0.7642644842698513,
        0.819863608484606,
        0.8156908653059846,
        0.7543081864399762,
        0.6423756436532483,
        0.49578004586443825,
        0.3606700693764785,
        0.2440576295833019,
        0.1656764856780825,
        0.12922447691984434,
        0.10404310896964158,
        0.09355019232162474,
        0.08506741084644912,
        0.07312944649834614,
        0.051624341712693866,
        0.028064246314605596,
        0.011497021394121176,
        0.0002962746906730719,
        0.000008971429487891228,
        0.00002328908333823101,
        0.00004313863816192856,
        0.00000945406377399817,
        0.000022380408897772513,
        0.00001602187276614816,
        0.000057367227382019736,
        0.0004046641545146183
      ],
      "range": 1
    }
  }
]
