    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M10 Mark II / prf-solomatov-pred-olympus-e-m10-mark-ii-7f5e8ad5f417@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M10 Mark II / prf-solomatov-pred-olympus-e-m10-mark-ii-7f5e8ad5f417@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26350772 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26350772; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.014597653533642204,
        0.024743607511764742,
        0.029058873113850327,
        0.0005973843954173335,
        0.012267458425885967,
        0.03289398504150087,
        0.05951868886421999,
        0.08296488239509643,
        0.11627867297398346,
        0.11161431627126522,
        0.09343047710328942,
        0.07440083728856217,
        0.05060158768782941,
        0.015600757351625218,
        0.000041812148805355684,
        0.00008504252550930955,
        0.022686735705504186,
        0.24666848470321856,
        0.5796948567578969,
        0.7460612918665154,
        0.7266550672595096,
        0.6650246148386089,
        0.5767303515813502,
        0.5043164200274664,
        0.43376518532360264,
        0.358639511586226,
        0.28738951177597377,
        0.20091541910043473,
        0.11826731300320158,
        0.04721853310407756,
        0.03281972535757206
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M10 Mark II / prf-solomatov-pred-olympus-e-m10-mark-ii-7f5e8ad5f417@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M10 Mark II / prf-solomatov-pred-olympus-e-m10-mark-ii-7f5e8ad5f417@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26350772 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26350772; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.019220560217362893,
        0.03298546623226067,
        0.06833746654557218,
        0.11309730508085303,
        0.16734219399720052,
        0.2105536035149179,
        0.2607723788889373,
        0.3461371454316405,
        0.45072702234302664,
        0.5609107012120935,
        0.692337932262478,
        0.8530680619148464,
        0.9641403295508761,
        1,
        0.9807088004859971,
        0.9205266168292906,
        0.8313036900778467,
        0.7075438624720368,
        0.5744198310394852,
        0.4401554155605005,
        0.32581836691539817,
        0.23362487064895102,
        0.1746242766625585,
        0.12778626751428765,
        0.0925308564014747,
        0.0638509414449034,
        0.04678402970508795,
        0.027938836099375003,
        0.016800862608503463,
        0.011040364206407312,
        0.004595909372218772
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M10 Mark II / prf-solomatov-pred-olympus-e-m10-mark-ii-7f5e8ad5f417@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M10 Mark II / prf-solomatov-pred-olympus-e-m10-mark-ii-7f5e8ad5f417@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26350772 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26350772; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.051295024677075876,
        0.12133117010765376,
        0.2819428971568651,
        0.4698228196122679,
        0.5968000482111113,
        0.6862592109255851,
        0.7574152666191336,
        0.7755032755776567,
        0.7359873175632198,
        0.6285948662149253,
        0.48379944997436886,
        0.3425670033500347,
        0.21694059665500504,
        0.12953059971070296,
        0.09019024945455108,
        0.06521860536002512,
        0.05774201985429497,
        0.05653569087084052,
        0.049755005280300704,
        0.03600620885035171,
        0.023021854539973248,
        0.014671739788117024,
        0.011751281897926937,
        0.0029028491840770356,
        0.000015900424852827842,
        0.000008091442254519147,
        0.000006956608330108886,
        0.00017557020340808232,
        0.000019861027221517455,
        0.000030890032367932144,
        0.00007113783231853702
      ],
      "range": 1
    }
  }
]