[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M10 Mark III / prf-solomatov-pred-olympus-e-m10-mark-iii-19cdf8824983@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M10 Mark III / prf-solomatov-pred-olympus-e-m10-mark-iii-19cdf8824983@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000512220716981 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27147698; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.017197370602104092,
        0.028336863019184727,
        0.03034953108310378,
        0.000051924232191569424,
        0.0015400329322414542,
        0.017036703427139775,
        0.04139847495180528,
        0.062401814428831415,
        0.09399816261585055,
        0.08780147542438076,
        0.07411940739874152,
        0.06294724763136274,
        0.055753523175901876,
        0.033089505415891986,
        0.0036602508140360086,
        0.002651983644164868,
        0.05482421750823956,
        0.2431627536154263,
        0.5318821075579304,
        0.668994344335524,
        0.6331348106691527,
        0.5591651046597994,
        0.473349718627245,
        0.39843398771522254,
        0.32617597885279265,
        0.25813571602050617,
        0.1971675780258188,
        0.1313221636802689,
        0.06949174274696276,
        0.02702548166304022,
        0.01786512333910806
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M10 Mark III / prf-solomatov-pred-olympus-e-m10-mark-iii-19cdf8824983@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M10 Mark III / prf-solomatov-pred-olympus-e-m10-mark-iii-19cdf8824983@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000512220716981 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27147698; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.02382968336762845,
        0.03867476261190751,
        0.07412455157251974,
        0.11222051390619686,
        0.15457776148694588,
        0.1884980940598025,
        0.23878834011923447,
        0.335405568645503,
        0.4551662914783174,
        0.5723198853974016,
        0.7097116691072666,
        0.8699011144553782,
        0.9745050454398352,
        1,
        0.9656769520295704,
        0.888703999875054,
        0.783903767825913,
        0.6473442930012355,
        0.5056464818033052,
        0.367533331236996,
        0.2535495520344549,
        0.1671925577473925,
        0.11943833643267929,
        0.08550586949295748,
        0.06218474991645701,
        0.03994145960651703,
        0.03247847051676018,
        0.017846513091503896,
        0.009610794862628438,
        0.007268177918084797,
        0.0010918172772618037
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M10 Mark III / prf-solomatov-pred-olympus-e-m10-mark-iii-19cdf8824983@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M10 Mark III / prf-solomatov-pred-olympus-e-m10-mark-iii-19cdf8824983@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000512220716981 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27147698; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06229401494741839,
        0.14767487288312672,
        0.3415922061745697,
        0.5634916876852948,
        0.6986980007727293,
        0.7839061214120051,
        0.8400487856882171,
        0.8335786114997789,
        0.7667129363970383,
        0.64538329458027,
        0.48894578391140203,
        0.3422174405170633,
        0.21995560423972937,
        0.1418437614857805,
        0.11404431922872568,
        0.09979408580559443,
        0.0988087788985171,
        0.09170026833317768,
        0.07039694933580208,
        0.047497000123334125,
        0.03522256012277727,
        0.024773522535749493,
        0.009143333495591889,
        0.000012047550123069458,
        0.00004673909206776944,
        0.00000767074671983663,
        0.0000058682050773669386,
        0.00048405500164323335,
        0.00001915920680619468,
        0.00001555815267080574,
        0.00003672963226147994
      ],
      "range": 1
    }
  }
]
