[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M10 Mark IV / prf-solomatov-pred-olympus-e-m10-mark-iv-939eaa42c653@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M10 Mark IV / prf-solomatov-pred-olympus-e-m10-mark-iv-939eaa42c653@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26541126 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26541126; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01057004891201677,
        0.020354954043773427,
        0.029409966630654632,
        0.0053182898118188365,
        0.032672061464159435,
        0.05316190051620267,
        0.06986660249455882,
        0.0791622329813739,
        0.09306826696048992,
        0.08677229443844998,
        0.07010962910917948,
        0.05436278400547136,
        0.043867460634488535,
        0.028832484349006145,
        0.006180318423566506,
        0.008254967404171172,
        0.06083227215002107,
        0.2464638840115525,
        0.5278437320255366,
        0.6851412031275538,
        0.6754606417225856,
        0.6221748090114941,
        0.5387379947632968,
        0.4723809758485756,
        0.4047459403191862,
        0.3351736998648814,
        0.2674061906793254,
        0.18912856221699112,
        0.11423258380220945,
        0.046673129090303106,
        0.0341249048740434
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M10 Mark IV / prf-solomatov-pred-olympus-e-m10-mark-iv-939eaa42c653@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M10 Mark IV / prf-solomatov-pred-olympus-e-m10-mark-iv-939eaa42c653@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26541126 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26541126; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.016573522540076106,
        0.028464377509831346,
        0.05980126464868145,
        0.09982048990687133,
        0.1446393043008047,
        0.17819560481345068,
        0.22597760923933674,
        0.3205922913745257,
        0.43502928248032885,
        0.5548272518656518,
        0.697705779325263,
        0.8620748795661496,
        0.9690923437084018,
        1,
        0.9739673441134337,
        0.9072324211112973,
        0.8140573237171627,
        0.6805340135154778,
        0.5370485788734057,
        0.40007861761403796,
        0.28816249167424174,
        0.20414117697945447,
        0.15195500748536445,
        0.10681584496452788,
        0.07117159987861857,
        0.0436624278864431,
        0.029203523618402626,
        0.013561527118329494,
        0.007555705812933484,
        0.005666326289246357,
        0.0012814986824598174
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M10 Mark IV / prf-solomatov-pred-olympus-e-m10-mark-iv-939eaa42c653@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M10 Mark IV / prf-solomatov-pred-olympus-e-m10-mark-iv-939eaa42c653@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26541126 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26541126; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04894047449230301,
        0.11853391977416483,
        0.2785472251629415,
        0.4657557859451781,
        0.6098096968455672,
        0.7139765283507565,
        0.7941198877545738,
        0.822206525827126,
        0.7957119453033004,
        0.688057206013038,
        0.5394740976701591,
        0.39081442889800533,
        0.2610105916380488,
        0.1657136927800275,
        0.12354694371293819,
        0.09141478021693579,
        0.07700238490258476,
        0.06623494798223709,
        0.053776731250965014,
        0.027993284836521255,
        0.00006379297170737972,
        0.000011452640705597797,
        0.000019432713593236398,
        0.000009295588288153262,
        0.000006088617340500173,
        0.000003938003609944809,
        0.000004263608484432801,
        0.000041280456601577495,
        0.000010355036934001972,
        0.00016685812802365657,
        0.0013934131882724194
      ],
      "range": 1
    }
  }
]
