[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M10 Mark IV / prf-solomatov-pred-olympus-e-m10-mark-iv-939eaa42c653@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M10 Mark IV / prf-solomatov-pred-olympus-e-m10-mark-iv-939eaa42c653@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000500775962264 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26541126; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.014005314808422221,
        0.026312501568780285,
        0.03711257693868322,
        0.006555101395962751,
        0.03935498312728295,
        0.06261290505241648,
        0.08049847678720908,
        0.08926804995771949,
        0.10276287810220762,
        0.09385574704567039,
        0.07431620685573025,
        0.05649465788803886,
        0.04471106564669024,
        0.028832484349006145,
        0.006065868082389348,
        0.00795478677129222,
        0.05757340042769851,
        0.22916817285284707,
        0.4823399620233352,
        0.6154658265383111,
        0.5966569001882839,
        0.5405781127476916,
        0.4605340922976569,
        0.3973998685710239,
        0.3351802318268261,
        0.27329547835136486,
        0.21473527433339765,
        0.14960916115672432,
        0.08903421972819267,
        0.035850374518638616,
        0.02583742797606143
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M10 Mark IV / prf-solomatov-pred-olympus-e-m10-mark-iv-939eaa42c653@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M10 Mark IV / prf-solomatov-pred-olympus-e-m10-mark-iv-939eaa42c653@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000500775962264 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26541126; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.021959917365600844,
        0.036795414829781985,
        0.07546350062809802,
        0.12303455732707395,
        0.17422461654415114,
        0.20987482344695302,
        0.26036550629749666,
        0.36151896686914603,
        0.48034483273869644,
        0.6001192724261133,
        0.7395681260847788,
        0.8958817375883515,
        0.9877287349335635,
        1,
        0.9559309118150368,
        0.8742421512527047,
        0.7704471099466004,
        0.6327772406371986,
        0.49075128759121556,
        0.3593926565007459,
        0.25454353431224686,
        0.17736856360509978,
        0.12989702252781155,
        0.08986094893841234,
        0.058938981149481,
        0.03560167196894591,
        0.023451314420838473,
        0.010727775183156167,
        0.00588900600125698,
        0.004352395555508071,
        0.0009702775738624331
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M10 Mark IV / prf-solomatov-pred-olympus-e-m10-mark-iv-939eaa42c653@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M10 Mark IV / prf-solomatov-pred-olympus-e-m10-mark-iv-939eaa42c653@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000500775962264 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26541126; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06484612870230148,
        0.15322677434221307,
        0.3515000698484738,
        0.5740710850021962,
        0.7345434984730695,
        0.8409056889464466,
        0.914964218499835,
        0.9271690610390995,
        0.8785986062723941,
        0.7442251411977758,
        0.5718425435303687,
        0.40614048493322125,
        0.2660300260926267,
        0.16571369278002748,
        0.12125903734788378,
        0.0880906063908654,
        0.07287725713994629,
        0.061586881457167814,
        0.049140806143123196,
        0.0251465101073835,
        0.00005635045834151875,
        0.000009950655039289889,
        0.00001661183581357305,
        0.00000782009808368449,
        0.000005042136235101706,
        0.0000032109875588780744,
        0.000003423806813256643,
        0.0000326546895505016,
        0.000008070837610325066,
        0.00012816638819208403,
        0.0010550128425491174
      ],
      "range": 1
    }
  }
]
