[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M5 Mark II / prf-solomatov-pred-olympus-e-m5-mark-ii-bc34ad2eeaa0@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M5 Mark II / prf-solomatov-pred-olympus-e-m5-mark-ii-bc34ad2eeaa0@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2687063 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2687063; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.015034947077906249,
        0.025647190631555714,
        0.029187279940961566,
        0.00008013736559209813,
        0.005940586432100773,
        0.024805318297338022,
        0.051092214808510256,
        0.071729538905489,
        0.10353251114692881,
        0.09788441878735259,
        0.08159860784804822,
        0.06310467599754825,
        0.04490216083508276,
        0.004637046842593568,
        0.00007964611547998689,
        0.000005813053880761262,
        0.003409553851175056,
        0.2796099309915696,
        0.6352740147886373,
        0.7808877573767343,
        0.7481687254820598,
        0.6706341459057715,
        0.5759855276932472,
        0.4929812587200225,
        0.41709102466149844,
        0.33699585755897793,
        0.26001042774211097,
        0.1737368383249667,
        0.09572017105665181,
        0.03771656265595559,
        0.02905340887057728
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M5 Mark II / prf-solomatov-pred-olympus-e-m5-mark-ii-bc34ad2eeaa0@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M5 Mark II / prf-solomatov-pred-olympus-e-m5-mark-ii-bc34ad2eeaa0@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2687063 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2687063; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.018422050394799078,
        0.03135996811388494,
        0.060760614842301795,
        0.09673765743490197,
        0.1373848882590397,
        0.1718445269053982,
        0.2190055015457397,
        0.30765817548751184,
        0.4203116190427988,
        0.5344393116201593,
        0.6716288750952248,
        0.8393591441659537,
        0.956697219231555,
        1,
        0.9862360875052054,
        0.9297691940977938,
        0.8399675779838432,
        0.7019580114050172,
        0.549392254666154,
        0.407059306015527,
        0.29477954182689425,
        0.20874951573520978,
        0.15623269718648203,
        0.11184415847339642,
        0.07805974776177559,
        0.048104290818637305,
        0.03395025349238183,
        0.017119312051857363,
        0.007366120556161131,
        0.00951932165341862,
        0.00017855813205719403
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M5 Mark II / prf-solomatov-pred-olympus-e-m5-mark-ii-bc34ad2eeaa0@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M5 Mark II / prf-solomatov-pred-olympus-e-m5-mark-ii-bc34ad2eeaa0@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2687063 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2687063; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04545991292351538,
        0.10789975523461862,
        0.26302844406699805,
        0.45767233592960044,
        0.5788814776579484,
        0.6563858011516663,
        0.7176762882001649,
        0.7246224967557515,
        0.6760510639311397,
        0.5777812801560663,
        0.44575986495292447,
        0.3205500950294057,
        0.215142778565296,
        0.14601735054220907,
        0.11976376437768671,
        0.10203728010843066,
        0.09922887554180904,
        0.09674418500794361,
        0.08611869167191093,
        0.062329550888832894,
        0.03631403134202659,
        0.015762228127885355,
        0.0010359674484744124,
        0.000022042572131728953,
        0.000032277226101509344,
        0.00000804128299187626,
        0.00005764242967135493,
        0.000023216550188812098,
        0.00003742204034665357,
        0.000009490481615057033,
        0.00035719223925899764
      ],
      "range": 1
    }
  }
]
