[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M5 Mark II / prf-solomatov-pred-olympus-e-m5-mark-ii-bc34ad2eeaa0@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M5 Mark II / prf-solomatov-pred-olympus-e-m5-mark-ii-bc34ad2eeaa0@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000506993018868 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2687063; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01992130487822578,
        0.033153685450547636,
        0.03683156754454674,
        0.00009877396224142328,
        0.007155706384121386,
        0.029215152661309227,
        0.0588671170619792,
        0.08088650131895568,
        0.11431714772473389,
        0.10587498358632015,
        0.08649452431893112,
        0.0655793691739227,
        0.04576566392806512,
        0.004637046842593568,
        0.00007817118741554269,
        0.000005601670103279034,
        0.003226899180576392,
        0.25998818144830155,
        0.5805090135137547,
        0.701475443067236,
        0.6608823741758194,
        0.5826821267705883,
        0.49237472528616294,
        0.4147302652723999,
        0.3454035047978034,
        0.27478123770193585,
        0.2087962525807861,
        0.13743361837646617,
        0.07460542744121391,
        0.028970693054574583,
        0.021997581002008514
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M5 Mark II / prf-solomatov-pred-olympus-e-m5-mark-ii-bc34ad2eeaa0@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M5 Mark II / prf-solomatov-pred-olympus-e-m5-mark-ii-bc34ad2eeaa0@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000506993018868 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2687063; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.02440921677310878,
        0.040538495366729314,
        0.07667410920576179,
        0.11923478707092569,
        0.16548634267566145,
        0.20239466502191344,
        0.25233242569400444,
        0.34693368725187507,
        0.464094079359757,
        0.5780670105279274,
        0.7119266076009383,
        0.8722751890352067,
        0.9750952426783156,
        1,
        0.967972456255109,
        0.8959594052215104,
        0.794969314877566,
        0.6526978000783494,
        0.5020308534018304,
        0.3656634443868293,
        0.26038859528042324,
        0.18137253006501833,
        0.13355375727231528,
        0.09409111744587319,
        0.06464322861522041,
        0.03922349866750426,
        0.027263082349942982,
        0.013542142369379706,
        0.005741241021713823,
        0.007311942719292563,
        0.00013519401427187548
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M5 Mark II / prf-solomatov-pred-olympus-e-m5-mark-ii-bc34ad2eeaa0@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M5 Mark II / prf-solomatov-pred-olympus-e-m5-mark-ii-bc34ad2eeaa0@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000506993018868 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2687063; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06023438462365788,
        0.13948017140084845,
        0.3319168460845452,
        0.5641077628899727,
        0.6972890526334379,
        0.7730766102452958,
        0.8268878972741032,
        0.8171274963415921,
        0.7464730497573,
        0.6249470989443165,
        0.4725054568500999,
        0.3331206869913431,
        0.21928013969155172,
        0.14601735054220907,
        0.11754591688921102,
        0.09832683355903317,
        0.09391304292349784,
        0.08995511939335107,
        0.07869466652778066,
        0.055990952493358365,
        0.032077394352123485,
        0.013695050668490553,
        0.000885585076921675,
        0.00001854375115843864,
        0.000026729577865312426,
        0.000006556738439529874,
        0.000046288617766391076,
        0.00001836533074637375,
        0.000029167178505479994,
        0.000007289790226058301,
        0.0002704455525818125
      ],
      "range": 1
    }
  }
]
