[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus STYLUS 1s / prf-solomatov-pred-olympus-stylus-1s-0e2632d8b648@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus STYLUS 1s / prf-solomatov-pred-olympus-stylus-1s-0e2632d8b648@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26703855 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26703855; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.011694020956899294,
        0.025431279491294423,
        0.022691952154473578,
        0.000060337707795372614,
        0.00001662436753045581,
        0.00991568895202584,
        0.036254409709759135,
        0.06109389824053494,
        0.09888479397450294,
        0.10497032731790973,
        0.09569821660580467,
        0.08780378713110898,
        0.07423573862275691,
        0.03873432131802693,
        0.00015280977222202564,
        0.00011085658980697732,
        0.0380297264196499,
        0.3059845853716627,
        0.6497084035245099,
        0.774027794863326,
        0.728794175971971,
        0.6566062839990706,
        0.5617521140674259,
        0.4783755004661312,
        0.40646684158523183,
        0.32773204468044037,
        0.2546958706898311,
        0.16961800459147192,
        0.096774023825399,
        0.040951978656265174,
        0.03228346993346092
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus STYLUS 1s / prf-solomatov-pred-olympus-stylus-1s-0e2632d8b648@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus STYLUS 1s / prf-solomatov-pred-olympus-stylus-1s-0e2632d8b648@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26703855 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26703855; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.0195607413236778,
        0.030541758858412014,
        0.058851660181647926,
        0.09287050877111189,
        0.13318309285307312,
        0.17130495203782375,
        0.23043287195800008,
        0.336246096303324,
        0.4610517470230422,
        0.5817719576443177,
        0.718448778275646,
        0.8750735053047585,
        0.9752186716112713,
        1,
        0.9707631351353578,
        0.9050828054601106,
        0.8121883900283312,
        0.6787982858654679,
        0.5343483553217316,
        0.39855708473551854,
        0.28577390792453,
        0.19723315229205673,
        0.14284105047754342,
        0.10136799724234573,
        0.06860509465768144,
        0.04358959970386299,
        0.03249359689827555,
        0.01599024747550494,
        0.008956075068562198,
        0.008554980544943792,
        0.002814168965492061
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus STYLUS 1s / prf-solomatov-pred-olympus-stylus-1s-0e2632d8b648@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus STYLUS 1s / prf-solomatov-pred-olympus-stylus-1s-0e2632d8b648@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26703855 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26703855; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04490525057149988,
        0.10919909129224975,
        0.25560519258361764,
        0.4405736175544692,
        0.5684765364401507,
        0.649326773231805,
        0.7122379147130631,
        0.7228086356820018,
        0.6933223686243054,
        0.6141571694423895,
        0.49704696194613107,
        0.3826596571918175,
        0.273185950118438,
        0.19316011115249093,
        0.15010433137837217,
        0.11563499726912088,
        0.09677642048311003,
        0.0873997218753622,
        0.07960428185368743,
        0.05569581620331596,
        0.027459843157476703,
        0.008597225007400617,
        0.0018855426304554158,
        0.0005400180985104961,
        0.004008579285649956,
        0.006615078983914495,
        0.00816193467197901,
        0.0061656116691766035,
        0.0037832814775245,
        0.0014469719821351638,
        0.0012579500600194242
      ],
      "range": 1
    }
  }
]
