    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus STYLUS 1s / prf-solomatov-pred-olympus-stylus-1s-0e2632d8b648@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus STYLUS 1s / prf-solomatov-pred-olympus-stylus-1s-0e2632d8b648@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000503846320755 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26703855; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.015494577767891567,
        0.03287458080581962,
        0.028635082480645235,
        0.00007436973286406393,
        0.00002002480634350359,
        0.011678478099052658,
        0.041771385100374654,
        0.06889311929251812,
        0.109185293346847,
        0.11353933362957583,
        0.10144010960215297,
        0.0912470729009564,
        0.07566334898088685,
        0.03873432131802693,
        0.00014997996162532148,
        0.0001068254410867236,
        0.03599241964716866,
        0.28451198288944074,
        0.5936990583930867,
        0.6953131038602759,
        0.6437681887752412,
        0.5704939844582089,
        0.48020745234796086,
        0.4024428813445231,
        0.33660535318777013,
        0.26722766720097446,
        0.204528502220622,
        0.13417543646788077,
        0.07542681268744333,
        0.03145586766350804,
        0.024443198663906127
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus STYLUS 1s / prf-solomatov-pred-olympus-stylus-1s-0e2632d8b648@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus STYLUS 1s / prf-solomatov-pred-olympus-stylus-1s-0e2632d8b648@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000503846320755 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26703855; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.025917982253873085,
        0.039480810231605774,
        0.07426519022922239,
        0.11446830150857978,
        0.16042508911847442,
        0.2017591657334369,
        0.2654987437776958,
        0.3791711298739611,
        0.5090779706712758,
        0.6292635460234457,
        0.7615557049721848,
        0.9093901133559256,
        0.993972876834565,
        1,
        0.9527860400402588,
        0.8721707034433793,
        0.7686782977053849,
        0.6311633184363122,
        0.4882838419319272,
        0.35802585577936413,
        0.2524336186666682,
        0.1713665093685083,
        0.12210605927919035,
        0.08527783894990991,
        0.056813594013392456,
        0.035542288989303665,
        0.026093342963766735,
        0.012649001734354655,
        0.00698047027402642,
        0.006571216940319145,
        0.0021307279310154178
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus STYLUS 1s / prf-solomatov-pred-olympus-stylus-1s-0e2632d8b648@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus STYLUS 1s / prf-solomatov-pred-olympus-stylus-1s-0e2632d8b648@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000503846320755 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26703855; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.05949945700723735,
        0.14115980093876188,
        0.3225494096888508,
        0.5430325983810901,
        0.684755827984727,
        0.7647626440285704,
        0.8206219452128771,
        0.8150820785350233,
        0.7655434486893373,
        0.6642924485805438,
        0.5268697796628989,
        0.39766591825816333,
        0.27843952608225414,
        0.19316011115249093,
        0.14732462153803197,
        0.11143008827751649,
        0.09159196938580058,
        0.08126640805954731,
        0.07274184376285231,
        0.050031834894504176,
        0.024256194789104426,
        0.007469720088397258,
        0.001611834829260275,
        0.00045430094001676656,
        0.00331960472092887,
        0.0053938336330379725,
        0.006554280872952841,
        0.004877274902482985,
        0.0029487340927764486,
        0.0011114422471472998,
        0.0009524479025861356
      ],
      "range": 1
    }
  }
]