    "model": "ESTIMATED PHOTON-RESPONSE MODEL / OM Digital Solutions OM 5 / prf-solomatov-pred-om-digital-solutions-om-5-275c036eb511@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / OM Digital Solutions OM 5 / prf-solomatov-pred-om-digital-solutions-om-5-275c036eb511@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000493944037736 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26179034; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.0164739143067693,
        0.02986513894305183,
        0.03171858742272264,
        0.00006740384611096678,
        0.00016399761307603493,
        0.023458929674622656,
        0.0598000634201499,
        0.09887460860570835,
        0.1464632982478778,
        0.1393708078902891,
        0.11532674078042754,
        0.08549656718485817,
        0.053704826497652805,
        0.0047278471008517725,
        0.00011138409801098423,
        0.00009199562957691464,
        0.00008074509998562753,
        0.21136185852777278,
        0.5438519908190917,
        0.6973729351381344,
        0.6671760189216046,
        0.5943708768414687,
        0.5078450127242551,
        0.4370803926652701,
        0.3753388413438975,
        0.3095929043535666,
        0.24494700693414706,
        0.17262959301991918,
        0.09598651376337802,
        0.03856865953401345,
        0.025832689297419123
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / OM Digital Solutions OM 5 / prf-solomatov-pred-om-digital-solutions-om-5-275c036eb511@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / OM Digital Solutions OM 5 / prf-solomatov-pred-om-digital-solutions-om-5-275c036eb511@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000493944037736 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26179034; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.024233248780302582,
        0.04072067896104914,
        0.07915950249130112,
        0.12740163715352043,
        0.17932623583437035,
        0.2208984745409458,
        0.2786983340578372,
        0.3811640773462279,
        0.5043301166434687,
        0.6210802733147729,
        0.7500800327468156,
        0.8952113598787097,
        0.9850320570093783,
        1,
        0.9640485574434474,
        0.8927454104893806,
        0.7933100109805425,
        0.6556332257627201,
        0.5085778915216315,
        0.3753515997391432,
        0.2720151941689929,
        0.19286009046681285,
        0.14214405745082975,
        0.09634603430884836,
        0.06167401602748213,
        0.03372244680756599,
        0.019237166686806535,
        0.006214296946357001,
        0.0031856809031406805,
        0.0040906696501892496,
        0.0005907006358054093
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / OM Digital Solutions OM 5 / prf-solomatov-pred-om-digital-solutions-om-5-275c036eb511@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / OM Digital Solutions OM 5 / prf-solomatov-pred-om-digital-solutions-om-5-275c036eb511@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000493944037736 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26179034; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06300342270077651,
        0.1502091906735786,
        0.3433464433517949,
        0.5662361160799028,
        0.7063419329098516,
        0.7905242815469983,
        0.8483010804022393,
        0.8466248089816631,
        0.7927525929082535,
        0.6798561624480388,
        0.5340567753569516,
        0.3978395635524333,
        0.27783001774508675,
        0.19109883886471898,
        0.14209085669541963,
        0.10591586312230548,
        0.08145318338113075,
        0.07667287360229871,
        0.08002468047654022,
        0.05912093611285158,
        0.026690452749326042,
        0.0041933146847556715,
        0.00030631049344985933,
        0.0000190983655815857,
        0.0038673089921404274,
        0.007888687495262281,
        0.010635447249562956,
        0.008834999896732903,
        0.004699207029114797,
        0.00197450951603574,
        0.0013642817345470312
      ],
      "range": 1
    }
  }
]