[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC GF10 / prf-solomatov-pred-panasonic-dc-gf10-fd245515f7b3@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC GF10 / prf-solomatov-pred-panasonic-dc-gf10-fd245515f7b3@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27095842 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27095842; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01102078761752449,
        0.022290668804460848,
        0.028361949409064315,
        0.012780595635300797,
        0.0335681836349651,
        0.05159739638281033,
        0.06629655575936708,
        0.07134758166954178,
        0.08630459610740276,
        0.08010201712867976,
        0.06734445454767563,
        0.057193050136622445,
        0.0539654608260559,
        0.03717823568649389,
        0.01538648992712609,
        0.014808159864528294,
        0.059500915306488725,
        0.2478764823030781,
        0.5278374076731035,
        0.66594405887073,
        0.6396165138547826,
        0.578154832759949,
        0.49360724793125094,
        0.4206315308452124,
        0.34716090387595266,
        0.2792855265394595,
        0.21278654857819146,
        0.14103621507683725,
        0.07827651194600264,
        0.031468470328399466,
        0.02221034762455435
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC GF10 / prf-solomatov-pred-panasonic-dc-gf10-fd245515f7b3@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC GF10 / prf-solomatov-pred-panasonic-dc-gf10-fd245515f7b3@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27095842 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27095842; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01801103837260344,
        0.030401325044632308,
        0.05772270520325591,
        0.09359039294663736,
        0.13191957644276198,
        0.16481153824265732,
        0.21832514376191006,
        0.31508531825657976,
        0.42799876822429067,
        0.5422348934570846,
        0.6834251543096539,
        0.8493902865244048,
        0.9635681371333654,
        1,
        0.9795760176044724,
        0.9157950876743377,
        0.8184474946377382,
        0.6759815768042935,
        0.5157424891981581,
        0.3711893138437994,
        0.2539404016306266,
        0.16758050921613732,
        0.11666245691866671,
        0.07794400705466176,
        0.04954051252587021,
        0.026296392634707573,
        0.018510375134310274,
        0.0062622519720922495,
        0.0023133501442767494,
        0.004456220995088472,
        0.00001473100559118997
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC GF10 / prf-solomatov-pred-panasonic-dc-gf10-fd245515f7b3@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC GF10 / prf-solomatov-pred-panasonic-dc-gf10-fd245515f7b3@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27095842 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27095842; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04602517242313415,
        0.10630300767180442,
        0.25225350074007663,
        0.4399213355318503,
        0.5836138622302272,
        0.6826415285415379,
        0.7654082128173024,
        0.8069547349737277,
        0.8000275466619565,
        0.7172483881475247,
        0.5798240925674132,
        0.4279539089429294,
        0.27716247016793205,
        0.1611183848798646,
        0.1031719848381165,
        0.05964587481725056,
        0.04449902682485379,
        0.043630192411071786,
        0.04851402661707284,
        0.03817485169864808,
        0.014745286011041843,
        0.0003424771003610075,
        0.0005285695495271933,
        0.00010312365269918536,
        0.0017475216308096278,
        0.008737046444247793,
        0.008686341985607977,
        0.009053233702794695,
        0.0025622359327309337,
        0.005049762247654087,
        0.00722017496263818
      ],
      "range": 1
    }
  }
]
