    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC GF9 / prf-solomatov-pred-panasonic-dc-gf9-f2f7dbf0a8f7@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC GF9 / prf-solomatov-pred-panasonic-dc-gf9-f2f7dbf0a8f7@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27693594 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27693594; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.012081788300933422,
        0.021735688766145702,
        0.02593623420636556,
        0.0010313937584265878,
        0.00749300831087507,
        0.02162987043140735,
        0.040350216010244105,
        0.052424734037770614,
        0.07799139396641692,
        0.07558901527912917,
        0.06857204593957722,
        0.06787935867045643,
        0.07046268534159922,
        0.05804564766855468,
        0.04020640296813769,
        0.04430475871062456,
        0.09793090777600048,
        0.30350795205562703,
        0.5773559040404795,
        0.6902619789977422,
        0.6527666289900834,
        0.5859570628499862,
        0.49783307287598716,
        0.4158513192617758,
        0.3399205462461824,
        0.2651835294472794,
        0.19823759603033106,
        0.12741332887309606,
        0.06943196682958522,
        0.026825832717848035,
        0.019827794832263376
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC GF9 / prf-solomatov-pred-panasonic-dc-gf9-f2f7dbf0a8f7@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC GF9 / prf-solomatov-pred-panasonic-dc-gf9-f2f7dbf0a8f7@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27693594 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27693594; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01762908274021783,
        0.02869114424079446,
        0.05537561141396093,
        0.0857679577450294,
        0.11964082379484585,
        0.15007801082084182,
        0.19935552604692625,
        0.29617551986932433,
        0.4141093062893895,
        0.5336980097274482,
        0.6737645897459175,
        0.8431075071007397,
        0.9588164685305923,
        1,
        0.9796628779926506,
        0.9143536949375368,
        0.8161228910917089,
        0.6803203657856759,
        0.5299466367565004,
        0.3813427755169661,
        0.2533752390534793,
        0.1562890212082982,
        0.10636277472689172,
        0.07667875466073491,
        0.05573074408471504,
        0.04011548302470239,
        0.03562280865387136,
        0.020100583550116322,
        0.011508961964272316,
        0.01024035016906798,
        0.0018649020419668175
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC GF9 / prf-solomatov-pred-panasonic-dc-gf9-f2f7dbf0a8f7@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC GF9 / prf-solomatov-pred-panasonic-dc-gf9-f2f7dbf0a8f7@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27693594 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27693594; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04618786387927837,
        0.1113258936344629,
        0.26038361073683686,
        0.44062323582847357,
        0.567021961829873,
        0.6580727297439256,
        0.7240827608002053,
        0.7428445004285107,
        0.7105103079073088,
        0.6208948538784818,
        0.48690119455062425,
        0.3504036348622718,
        0.22650086514592507,
        0.14127802263584857,
        0.1084310364339132,
        0.08695585701155292,
        0.08639721879363148,
        0.07918604930800964,
        0.06495784548585495,
        0.04831167092288563,
        0.0391269583861163,
        0.03003048286184885,
        0.017099351568452978,
        0.0024964282353529123,
        0.00003509749944337308,
        0.000012520437036810752,
        0.00009705454264982725,
        0.00004484443767031466,
        0.00009465269838216015,
        0.0005039769486040707,
        0.0008631894437392272
      ],
      "range": 1
    }
  }
]