[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC GF9 / prf-solomatov-pred-panasonic-dc-gf9-f2f7dbf0a8f7@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC GF9 / prf-solomatov-pred-panasonic-dc-gf9-f2f7dbf0a8f7@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000522520641509 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27693594; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.016008369498736782,
        0.02809735377087127,
        0.03272905745088987,
        0.0012712527720141662,
        0.00902566910173588,
        0.025475180730324214,
        0.04649046627267255,
        0.059117253276634946,
        0.08611549750458536,
        0.08175954713864993,
        0.07268636869595185,
        0.07054129430459198,
        0.07181773698278382,
        0.05804564766855468,
        0.039461839950209215,
        0.04269367657569276,
        0.0926846091451433,
        0.28220914840260053,
        0.5275838433473348,
        0.6200658455403447,
        0.5766105222745737,
        0.509110234935234,
        0.42556698165205353,
        0.3498431733472082,
        0.2814967023601198,
        0.21622657016470473,
        0.15919079681223552,
        0.10078964821304613,
        0.0541160917936473,
        0.02060534976878182,
        0.015012473230142268
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC GF9 / prf-solomatov-pred-panasonic-dc-gf9-f2f7dbf0a8f7@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC GF9 / prf-solomatov-pred-panasonic-dc-gf9-f2f7dbf0a8f7@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000522520641509 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27693594; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.023358534630788623,
        0.03708855231127088,
        0.06987874773666498,
        0.10571399442991998,
        0.14411281048015523,
        0.17675854607788036,
        0.22969223653232806,
        0.33398516070370615,
        0.45724569236120094,
        0.577265194194995,
        0.7141904651306725,
        0.8761705465948864,
        0.9772552467715652,
        1,
        0.9615209728446384,
        0.8811044696670809,
        0.7724020219260815,
        0.6325785857305408,
        0.48426158186369866,
        0.3425621542779526,
        0.22381479449724004,
        0.13579210039409514,
        0.09092301710524615,
        0.06450752376220556,
        0.04615202244515464,
        0.03270954769706503,
        0.02860619482810882,
        0.015900461614271118,
        0.008970220354506363,
        0.007865776216820334,
        0.0014119972603463047
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC GF9 / prf-solomatov-pred-panasonic-dc-gf9-f2f7dbf0a8f7@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC GF9 / prf-solomatov-pred-panasonic-dc-gf9-f2f7dbf0a8f7@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000522520641509 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27693594; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.061198919640043835,
        0.1439090820152813,
        0.3285793183107703,
        0.5430937557885837,
        0.6830037267496197,
        0.7750634372539569,
        0.8342692678784974,
        0.8376757132491717,
        0.7845217983143201,
        0.6715801480726435,
        0.5161152662236618,
        0.3641449538764785,
        0.23085665101411593,
        0.14127802263584857,
        0.10642305427772962,
        0.08379382584749645,
        0.08176879635825836,
        0.07362913356709669,
        0.05935803121983298,
        0.04339861964259218,
        0.034562146574402736,
        0.026092058879967035,
        0.0146171876310969,
        0.0021001697852968946,
        0.00002906511672654333,
        0.000010208971737707227,
        0.00007793773879455825,
        0.00003547395815711458,
        0.00007377342668021307,
        0.0003871127286379093,
        0.000653557721688272
      ],
      "range": 1
    }
  }
]
