[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC LX100M2 / prf-solomatov-pred-panasonic-dc-lx100m2-0fd1fe5eccdc@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC LX100M2 / prf-solomatov-pred-panasonic-dc-lx100m2-0fd1fe5eccdc@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27353385 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27353385; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.010928102682720986,
        0.0232857447076477,
        0.027591121537608596,
        0.0005571156915314137,
        0.014934292775830119,
        0.03249061861996239,
        0.05540995748789409,
        0.0695017819549573,
        0.09446367241202505,
        0.09132693083506849,
        0.07614357418652207,
        0.06037025764818504,
        0.05161601754225299,
        0.025851060115594467,
        0.00001748566402293537,
        0.000027448299360389944,
        0.038926381506347384,
        0.2569823442327156,
        0.583469833806675,
        0.7203930336227125,
        0.6782432229137271,
        0.6123223140390119,
        0.5229152077521666,
        0.44640880826998186,
        0.37390717821578573,
        0.2970033690528613,
        0.22238667718821636,
        0.14806151414166838,
        0.08060774196685346,
        0.03351384846884581,
        0.024201063232210565
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC LX100M2 / prf-solomatov-pred-panasonic-dc-lx100m2-0fd1fe5eccdc@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC LX100M2 / prf-solomatov-pred-panasonic-dc-lx100m2-0fd1fe5eccdc@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27353385 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27353385; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.016799513113276474,
        0.02824053768847987,
        0.056719009365751256,
        0.0920286977279046,
        0.12979788059137837,
        0.1606228369907417,
        0.21072618982988758,
        0.30122487582432667,
        0.41050864454253094,
        0.5232305617750782,
        0.6661560534464016,
        0.8381904104373187,
        0.9570944510158431,
        1,
        0.9824848368858186,
        0.9206691603251298,
        0.8249381200900728,
        0.6786394810002491,
        0.5124701019636144,
        0.36546083784511496,
        0.2527940874593766,
        0.16713958802539428,
        0.11829888695676968,
        0.08083259165181932,
        0.050814661512642766,
        0.0282706644899708,
        0.018811261202224146,
        0.005831300586746393,
        0.0024528722861905388,
        0.0051338424842117345,
        0.000014819657603620171
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC LX100M2 / prf-solomatov-pred-panasonic-dc-lx100m2-0fd1fe5eccdc@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC LX100M2 / prf-solomatov-pred-panasonic-dc-lx100m2-0fd1fe5eccdc@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27353385 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27353385; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.045416305879509976,
        0.10426667485578109,
        0.249956610488976,
        0.4368235960558446,
        0.573029919331739,
        0.6648052882668817,
        0.7379994103106434,
        0.7614589931008537,
        0.7359173279650764,
        0.6445218023290353,
        0.5067762180073874,
        0.36719318285469965,
        0.2387041311340443,
        0.14512746777044228,
        0.10234539162154885,
        0.072765250077824,
        0.06417543203519417,
        0.06488475557961107,
        0.07097241529704641,
        0.05561095637706265,
        0.028658504239968834,
        0.010258825370242109,
        0.000770321771875766,
        0.00004691204397554452,
        0.00019264179917768859,
        0.0003306129753227982,
        0.0008848224817513444,
        0.0005276192325008404,
        0.000002950472126210339,
        0.00012125007563049326,
        0.0018481611690838262
      ],
      "range": 1
    }
  }
]
