[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC FZ150 / prf-solomatov-pred-panasonic-dmc-fz150-1c68831f0038@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC FZ150 / prf-solomatov-pred-panasonic-dmc-fz150-1c68831f0038@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26798397 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26798397; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.009912258557853292,
        0.02435795917196092,
        0.0295045408872777,
        0.005094011779883699,
        0.022668389456279792,
        0.04386730669002328,
        0.06664181070233416,
        0.07884022689864621,
        0.10019808274353126,
        0.09240484794668875,
        0.07290343896315887,
        0.0534067112297799,
        0.0395717773716092,
        0.007075140352611389,
        0.002802456803666279,
        0.005014108866287785,
        0.00840089763578023,
        0.22732900777609943,
        0.5800955183998505,
        0.765830657706877,
        0.7409992097661662,
        0.6694169804261052,
        0.5776290649026508,
        0.5125367013556819,
        0.44955162803207965,
        0.378200457288546,
        0.3086334081848254,
        0.21761274004560793,
        0.12419709283357508,
        0.048345917854713476,
        0.04027043110078562
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC FZ150 / prf-solomatov-pred-panasonic-dmc-fz150-1c68831f0038@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC FZ150 / prf-solomatov-pred-panasonic-dmc-fz150-1c68831f0038@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26798397 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26798397; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01855735997940474,
        0.029876815019943166,
        0.062205489380577496,
        0.10770356898586135,
        0.1571677514890163,
        0.19433597091646934,
        0.2449206943236194,
        0.33705038402110393,
        0.45131203183533697,
        0.572299865547928,
        0.7094568753496711,
        0.866298570022677,
        0.9684415079006404,
        1,
        0.9786205868955519,
        0.9169114107832643,
        0.82497311313061,
        0.687768600487559,
        0.527024545535317,
        0.38566082889211617,
        0.27442301866040714,
        0.18963952955842842,
        0.13842208547026152,
        0.09380926777075509,
        0.058878316490348276,
        0.032408837737570646,
        0.01909201509329084,
        0.005685978157574126,
        0.0026191305397856445,
        0.005577275760188193,
        0.0013838006803168115
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC FZ150 / prf-solomatov-pred-panasonic-dmc-fz150-1c68831f0038@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC FZ150 / prf-solomatov-pred-panasonic-dmc-fz150-1c68831f0038@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26798397 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26798397; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04856215466917667,
        0.12226299953687529,
        0.282296362726472,
        0.4614282936401009,
        0.5806083848970519,
        0.668400800241895,
        0.7278430870324071,
        0.7289562506294686,
        0.6755814909376856,
        0.5630941656696854,
        0.4283953999188832,
        0.30798316033604545,
        0.20937235163730128,
        0.1421622718702167,
        0.11166636944739641,
        0.08725365923939404,
        0.0748789563793685,
        0.06782906828344994,
        0.061246872340909045,
        0.04557721866722103,
        0.02310907253146522,
        0.008926313017901779,
        0.004979126176838115,
        0.004765667513620311,
        0.005575186829271914,
        0.005713735414845895,
        0.0057584843600906425,
        0.0038093319536985737,
        0.0023295624734569007,
        0.0011551720052509111,
        0.0014564895803282562
      ],
      "range": 1
    }
  }
]
