[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC FZ28 / prf-solomatov-pred-panasonic-dmc-fz28-22efa4d0153f@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC FZ28 / prf-solomatov-pred-panasonic-dmc-fz28-22efa4d0153f@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27384904 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27384904; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.012007663784397419,
        0.02303874317032479,
        0.02411283384451521,
        0.0015078754338521691,
        0.000028807851581294573,
        0.009578534217246115,
        0.03367549873463131,
        0.057853268355441384,
        0.09366244263627874,
        0.0925430375801208,
        0.08127230608513362,
        0.06798895479056637,
        0.05560808611927214,
        0.026457649805893057,
        0.000017494105511562136,
        0.000059616068035148126,
        0.03949694693105369,
        0.27048349703909863,
        0.5903549634499358,
        0.7324181600198416,
        0.707388384490959,
        0.6427923574243679,
        0.5497883797584245,
        0.4696795723658553,
        0.3966998021975903,
        0.3169570724074841,
        0.24830158250691697,
        0.1664753325408773,
        0.09631573658246165,
        0.03721690607350678,
        0.025348471917228558
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC FZ28 / prf-solomatov-pred-panasonic-dmc-fz28-22efa4d0153f@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC FZ28 / prf-solomatov-pred-panasonic-dmc-fz28-22efa4d0153f@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27384904 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27384904; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.017546897370901867,
        0.028639267824345855,
        0.055136041375204385,
        0.08639514310512099,
        0.12213575771527262,
        0.1529719330036724,
        0.19975915927987187,
        0.2920987782173711,
        0.4131929036523188,
        0.5325291627825316,
        0.6743003006327867,
        0.8403976512022828,
        0.9567609585193361,
        1,
        0.9823491438932924,
        0.9232918983393186,
        0.8290639616629658,
        0.6953407614647836,
        0.5455982609981032,
        0.4018805579891754,
        0.2817620613167021,
        0.1911745135202957,
        0.1403470795442628,
        0.10107482575071287,
        0.07082953805498095,
        0.04565739576812101,
        0.035856092466126595,
        0.019140465126333838,
        0.009204994839492591,
        0.009047165547850743,
        0.0008147311745186327
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC FZ28 / prf-solomatov-pred-panasonic-dmc-fz28-22efa4d0153f@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC FZ28 / prf-solomatov-pred-panasonic-dmc-fz28-22efa4d0153f@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27384904 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27384904; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04291111263344213,
        0.11016575044411331,
        0.26293129966787543,
        0.45089623100376763,
        0.5732803372252099,
        0.6511662775958609,
        0.7110137395405878,
        0.7146081651409112,
        0.6659240068908038,
        0.5684960224801227,
        0.43715712861363326,
        0.31294318212691197,
        0.20779465942257822,
        0.14158450217681975,
        0.11593630928923469,
        0.10294116422683096,
        0.10164413941345203,
        0.0993958897938806,
        0.08750048566903867,
        0.06609912526989323,
        0.04692807212323987,
        0.028742289912719796,
        0.009779816646426805,
        0.000001705404736857942,
        0.00001308167485268526,
        0.000037828315921794,
        0.000016868611261153227,
        0.000017637010522293595,
        0.000019211694150908835,
        0.00006968181447705641,
        0.00014543428744537501
      ],
      "range": 1
    }
  }
]
