[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC FZ30 / prf-solomatov-pred-panasonic-dmc-fz30-dcae2fbc56e0@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC FZ30 / prf-solomatov-pred-panasonic-dmc-fz30-dcae2fbc56e0@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26855204 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26855204; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.009979327284201601,
        0.02508250765847841,
        0.026540312261266012,
        0.0009965531075466789,
        0.0073847214119095875,
        0.023791437220138042,
        0.05490359335940997,
        0.0801943898843591,
        0.11597934612598736,
        0.11853494019259732,
        0.10655329224086325,
        0.09315477923757347,
        0.07313004957996223,
        0.031926415453779465,
        0.00006158112595234802,
        0.0000326048724113211,
        0.02043721954225334,
        0.2984255863407331,
        0.6488128334456145,
        0.7850202888051047,
        0.7435189470167495,
        0.6682304479980863,
        0.574707829439687,
        0.492841722594995,
        0.426586333136773,
        0.35232865853485973,
        0.28044203276206725,
        0.19650379122050238,
        0.1147329359330132,
        0.04905721997122047,
        0.03507558535023603
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC FZ30 / prf-solomatov-pred-panasonic-dmc-fz30-dcae2fbc56e0@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC FZ30 / prf-solomatov-pred-panasonic-dmc-fz30-dcae2fbc56e0@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26855204 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26855204; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.019315748634789742,
        0.03204561395251364,
        0.0635589362866132,
        0.09930515888093794,
        0.14197862730813737,
        0.18588296704057805,
        0.2463985527721182,
        0.352119946659128,
        0.48511033466735165,
        0.6080952131288968,
        0.7374974325274163,
        0.8815723015919,
        0.9737543978440827,
        1,
        0.9744466286683208,
        0.9132596423397119,
        0.8221408409334742,
        0.6888854763493883,
        0.5438467345100041,
        0.40578094286679034,
        0.2903628287463391,
        0.19782846185044806,
        0.1442954408389525,
        0.09979464315370683,
        0.06717887527497464,
        0.042106863161419296,
        0.031113597200751106,
        0.015620210518601907,
        0.008258541994318866,
        0.008037667485229306,
        0.004965786519439584
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC FZ30 / prf-solomatov-pred-panasonic-dmc-fz30-dcae2fbc56e0@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC FZ30 / prf-solomatov-pred-panasonic-dmc-fz30-dcae2fbc56e0@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26855204 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26855204; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04434642164699252,
        0.10987103654099967,
        0.25881062009434,
        0.43805430038811105,
        0.5486308352005071,
        0.6178834091150452,
        0.6669035915720469,
        0.6625180356105282,
        0.6122469596581728,
        0.5298378295692708,
        0.4261914748441308,
        0.3349951465645169,
        0.2549806733920174,
        0.1974681704149408,
        0.16414193688493298,
        0.13509939079219058,
        0.11341326247233126,
        0.10179944639407693,
        0.09124214807677498,
        0.0648986915161769,
        0.03437942605090619,
        0.012965998694331274,
        0.00674659406795048,
        0.004893632533940163,
        0.007087109075767959,
        0.008341114444708742,
        0.00932187929013684,
        0.006735527683945354,
        0.0038684021912475516,
        0.0018144526476134757,
        0.0016936562462902907
      ],
      "range": 1
    }
  }
]
