[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC GX1 / prf-solomatov-pred-panasonic-dmc-gx1-af516ad226a4@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC GX1 / prf-solomatov-pred-panasonic-dmc-gx1-af516ad226a4@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26707044 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26707044; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.009526802741628763,
        0.021900997354855144,
        0.03208904362459582,
        0.011651456821653493,
        0.04243703271691169,
        0.062329073183838686,
        0.07343131272783315,
        0.07475139517499577,
        0.08225242374259015,
        0.06416664083078606,
        0.04361159550266963,
        0.02132729365331483,
        0.009966617046798588,
        0.00007165404752394161,
        0.00009759401676950844,
        5.449819905190555e-7,
        0.016495243726711198,
        0.20967065842254948,
        0.5004504804050945,
        0.6596779111907705,
        0.6453427043442171,
        0.5904767296597856,
        0.5120648694778801,
        0.4409884748008802,
        0.3740337343211776,
        0.30571777243486775,
        0.23903042208639785,
        0.16715940184170136,
        0.09692310013792615,
        0.040001562883559855,
        0.026049822286584767
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC GX1 / prf-solomatov-pred-panasonic-dmc-gx1-af516ad226a4@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC GX1 / prf-solomatov-pred-panasonic-dmc-gx1-af516ad226a4@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26707044 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26707044; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.017109877828485998,
        0.03023968133650433,
        0.06046346798994302,
        0.10303201657210734,
        0.14611831994585397,
        0.17689147851780226,
        0.22189569163850553,
        0.30587158953270904,
        0.40739098643788507,
        0.5169093217504716,
        0.6597347126847882,
        0.8328180385669038,
        0.9548089635079045,
        1,
        0.9892530225359271,
        0.9325140588378107,
        0.8387071964984218,
        0.6942440353938084,
        0.5310011471130986,
        0.384932192420846,
        0.27084626063446027,
        0.1870275871788731,
        0.13425501901296152,
        0.08884524996476584,
        0.054097009013801746,
        0.027832499920245758,
        0.014957801395017734,
        0.0016576012680399972,
        0.0000010657778524646905,
        0.0017257507045706742,
        0.0002725354779061284
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC GX1 / prf-solomatov-pred-panasonic-dmc-gx1-af516ad226a4@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC GX1 / prf-solomatov-pred-panasonic-dmc-gx1-af516ad226a4@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26707044 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26707044; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.048007776525174406,
        0.11406036924191235,
        0.2696439935471705,
        0.4598866875720128,
        0.6016949685633498,
        0.7085126306003764,
        0.8006070982621663,
        0.8481245621941537,
        0.8443993277578753,
        0.7463282346035749,
        0.5914935026130185,
        0.4186407900477492,
        0.25557163870325744,
        0.1361124690549804,
        0.08136945818488935,
        0.04701136898565037,
        0.042378967511342694,
        0.04833596709542246,
        0.04941540890860104,
        0.03607884496689338,
        0.018543146894130252,
        0.008813161052192821,
        0.005783512394707553,
        0.0004242794672446714,
        0.00009748472350590352,
        0.000049087296969293936,
        0.000169724200851281,
        0.000012310847280590093,
        0.000008439472372906563,
        0.00001747231554341993,
        0.0007951318760698489
      ],
      "range": 1
    }
  }
]
