    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC GX8 / prf-solomatov-pred-panasonic-dmc-gx8-e27f93a3e8eb@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC GX8 / prf-solomatov-pred-panasonic-dmc-gx8-e27f93a3e8eb@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.28518745 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28518745; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.008948573298018549,
        0.018259986545691262,
        0.021695167161107545,
        0.0017587787961917678,
        0.019258379006509577,
        0.025136935724205254,
        0.02590291543334042,
        0.015513096035607457,
        0.01434138844468787,
        0.01224196401349358,
        0.014267959547308268,
        0.03283986725222306,
        0.061741416040572615,
        0.07906187316447481,
        0.08101026886000769,
        0.09846466946564443,
        0.15328216581760523,
        0.3170912675154534,
        0.5232801092754957,
        0.6130907934412962,
        0.5848738084372226,
        0.5217624057440114,
        0.44105966093529014,
        0.3661148833863482,
        0.29596176129068796,
        0.22706830191861524,
        0.1682659387711486,
        0.108767770110501,
        0.05965138718411347,
        0.02311557538734611,
        0.013918754138725248
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC GX8 / prf-solomatov-pred-panasonic-dmc-gx8-e27f93a3e8eb@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC GX8 / prf-solomatov-pred-panasonic-dmc-gx8-e27f93a3e8eb@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.28518745 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28518745; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.015172879101096487,
        0.023657934456793244,
        0.04459858594759341,
        0.07047315370995463,
        0.09309419120652049,
        0.11069643843023247,
        0.15705698129423296,
        0.25825598566837354,
        0.3793586639243767,
        0.5038801321727165,
        0.6584361969644877,
        0.8408995557132686,
        0.9609459672927402,
        1,
        0.9710113821628545,
        0.8959771897395905,
        0.7863873743392285,
        0.6402779996104316,
        0.4816417061830736,
        0.32762241115448804,
        0.19755073373670545,
        0.1049797983747181,
        0.06296685916578727,
        0.043481548714713776,
        0.030357215929382585,
        0.022541502790533033,
        0.025005810038274824,
        0.013203013316329311,
        0.006107832234553098,
        0.007135524371777229,
        0.0002509143021546004
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC GX8 / prf-solomatov-pred-panasonic-dmc-gx8-e27f93a3e8eb@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC GX8 / prf-solomatov-pred-panasonic-dmc-gx8-e27f93a3e8eb@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.28518745 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28518745; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04469530829635035,
        0.10460253773439188,
        0.253619575475709,
        0.4404251309095123,
        0.5798026876708635,
        0.6744255050493982,
        0.748028463384346,
        0.7688450175489839,
        0.7385189635799191,
        0.6389681242985973,
        0.49180375924676906,
        0.34044154467526533,
        0.20944835405625317,
        0.12026917734283187,
        0.0943553652168074,
        0.0789182167728629,
        0.0814639073353333,
        0.06358541022755385,
        0.036127112185336346,
        0.021473714919783463,
        0.018226953184651007,
        0.015179016467940648,
        0.0048246428796218065,
        0.00002376907328846343,
        0.00004012689899222424,
        0.00004064444280419773,
        0.000033033659089837225,
        0.000040827550440946824,
        0.000005899539057556705,
        0.00002779797989006879,
        0.0027196352784808727
      ],
      "range": 1
    }
  }
]