[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC L1 / prf-solomatov-pred-panasonic-dmc-l1-a1783747aed6@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC L1 / prf-solomatov-pred-panasonic-dmc-l1-a1783747aed6@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26591772 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26591772; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.011103589862307783,
        0.018274497464854916,
        0.02837266918503964,
        0.009974146890248607,
        0.04493300784919485,
        0.057151400064651574,
        0.059851144933101855,
        0.03907245068136113,
        0.027286010123733006,
        0.016575051861906758,
        0.0015046152621946366,
        0.0000702853273561461,
        0.002177340682674325,
        0.00004993784355551785,
        0.000024633625017543017,
        0.000060324908020420756,
        0.011052973077536915,
        0.22471195225350155,
        0.5473249394587167,
        0.7187882778176647,
        0.6989070529034319,
        0.6353965805663496,
        0.5468949568310076,
        0.4821729067171604,
        0.4207462594068571,
        0.35787077295939507,
        0.28971845125627577,
        0.2085334704283716,
        0.12087653654671826,
        0.051718990370404797,
        0.034122287901686275
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC L1 / prf-solomatov-pred-panasonic-dmc-l1-a1783747aed6@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC L1 / prf-solomatov-pred-panasonic-dmc-l1-a1783747aed6@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26591772 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26591772; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01504091340735021,
        0.026343854031239435,
        0.05219209159885998,
        0.08708015772698412,
        0.11670893538046279,
        0.13828751239293116,
        0.18326017536552283,
        0.27645284413539645,
        0.3902135592919494,
        0.5134229866290971,
        0.6599893756610127,
        0.8346731462649424,
        0.9546818467005507,
        1,
        0.9849118742444091,
        0.9303554497985316,
        0.8394780159817856,
        0.6876720739031607,
        0.5103718548730035,
        0.3615206613534442,
        0.2559592493497613,
        0.1736866501412542,
        0.12580981816480677,
        0.07831411911925237,
        0.039035537007462304,
        0.006441891123314384,
        0.000004472527065890907,
        0.000011797862135701223,
        0.000025353115993924734,
        0.000021215120601966652,
        0.00007133324548661142
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC L1 / prf-solomatov-pred-panasonic-dmc-l1-a1783747aed6@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC L1 / prf-solomatov-pred-panasonic-dmc-l1-a1783747aed6@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26591772 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26591772; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04883911083473489,
        0.11683344381863682,
        0.2783146606401408,
        0.4745240745896888,
        0.614528396227224,
        0.7193349506757203,
        0.8016896354255745,
        0.8317478429041885,
        0.8056024622954799,
        0.7002089593728466,
        0.5476311620000351,
        0.3892866560378149,
        0.24839390169259873,
        0.1507393941253708,
        0.10977588857184845,
        0.07962219290989708,
        0.06723572238811312,
        0.052701153198816526,
        0.03326120575943566,
        0.008946295493207447,
        0.000017746805289997218,
        0.000003901763297308656,
        9.214105776779372e-7,
        0.000025396735501492717,
        0.000007503995972889658,
        0.000005220092139779177,
        0.00006757796358963967,
        0.000004053888548683405,
        0.0000029033196057788096,
        0.000003712639383340079,
        0.000947492893666507
      ],
      "range": 1
    }
  }
]
