    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC LX2 / prf-solomatov-pred-panasonic-dmc-lx2-08af14892f5f@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC LX2 / prf-solomatov-pred-panasonic-dmc-lx2-08af14892f5f@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000510431018868 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27052844; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.014658975401994706,
        0.028800021642195063,
        0.043036560134640474,
        0.028274896871694766,
        0.06660924986129169,
        0.09345319807739583,
        0.10769220804835997,
        0.10351085893774925,
        0.10665297657798938,
        0.0909509732816533,
        0.06790336934630607,
        0.05107903431738355,
        0.04329249193797262,
        0.020435610023108848,
        0.002874700845445992,
        0.005212709351707751,
        0.02840531440190593,
        0.20835298136323066,
        0.48331259711930646,
        0.6133880183865829,
        0.578244344661138,
        0.51994806965188,
        0.4439030519722449,
        0.38300540923910215,
        0.3262743766422488,
        0.2744463664693272,
        0.2190646409514563,
        0.15130822596085725,
        0.08918372229073544,
        0.037584925063433396,
        0.02811171799270241
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC LX2 / prf-solomatov-pred-panasonic-dmc-lx2-08af14892f5f@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC LX2 / prf-solomatov-pred-panasonic-dmc-lx2-08af14892f5f@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000510431018868 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27052844; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.022778817450764148,
        0.03947097455162832,
        0.07805389386364385,
        0.12855609510210875,
        0.17980426660501944,
        0.2173151019209334,
        0.27791146147308876,
        0.38069411521532814,
        0.5003195235529889,
        0.6175508352527841,
        0.7536946341020561,
        0.9055403477987707,
        0.9909229058675509,
        1,
        0.9542778563866144,
        0.8723998166497595,
        0.7642629881300887,
        0.6162416281104844,
        0.45597343060148865,
        0.32196850463535587,
        0.21913124241823398,
        0.1467923340981857,
        0.1044857529879835,
        0.06765460610211278,
        0.04039147343205395,
        0.021138882904084378,
        0.012563578752038274,
        0.0034060833545556638,
        0.0012538588897040353,
        0.0035358966003882913,
        0.0010352110452522374
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC LX2 / prf-solomatov-pred-panasonic-dmc-lx2-08af14892f5f@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC LX2 / prf-solomatov-pred-panasonic-dmc-lx2-08af14892f5f@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000510431018868 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27052844; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06659109408238188,
        0.15386277722800967,
        0.34696815627820515,
        0.5613901186258119,
        0.704193275138903,
        0.8015195140953676,
        0.8704117417457992,
        0.8812144954739601,
        0.8345042900110615,
        0.7085152145714725,
        0.5490507230958787,
        0.3944975843516911,
        0.26086880665002293,
        0.1631376168805025,
        0.11306156463144396,
        0.07384190734253301,
        0.05176274158880619,
        0.04336680292785354,
        0.04245674340318833,
        0.026827493313657663,
        0.000008967150958324382,
        0.00013821863499792494,
        0.00001542491768833931,
        0.00003283110793341511,
        0.00015630656406217402,
        0.0055222228703996476,
        0.00919080056571479,
        0.006409646489188502,
        0.00394695350699542,
        0.0019511683905380345,
        0.0025716485704793185
      ],
      "range": 1
    }
  }
]