[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC LX9 / prf-solomatov-pred-panasonic-dmc-lx9-5ca70bc86399@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC LX9 / prf-solomatov-pred-panasonic-dmc-lx9-5ca70bc86399@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000519368622642 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27526537; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.013177548087505524,
        0.02519436318806848,
        0.027502710289381935,
        0.000450704198136021,
        0.00040099330577550744,
        0.01194644496448403,
        0.03474961310496723,
        0.053734261457233534,
        0.08636196295778144,
        0.08218042999519974,
        0.07416086440513749,
        0.06779512140038026,
        0.06021252866195712,
        0.04199627072595438,
        0.01831101861747017,
        0.01757226959173648,
        0.06824772128074084,
        0.26311074438280696,
        0.5212609587964341,
        0.6286132868186465,
        0.5885474914625113,
        0.5265345511234737,
        0.4449597744005498,
        0.37056819313541256,
        0.3028298315367458,
        0.23649533008260912,
        0.17874651016790002,
        0.11676932862190838,
        0.06432155146055862,
        0.026095717974869544,
        0.018577311829256673
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC LX9 / prf-solomatov-pred-panasonic-dmc-lx9-5ca70bc86399@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC LX9 / prf-solomatov-pred-panasonic-dmc-lx9-5ca70bc86399@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000519368622642 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27526537; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.024780070337216777,
        0.035635820152430345,
        0.06765042783121993,
        0.10220467253109246,
        0.14166330822705905,
        0.1736288093356765,
        0.22456586734908712,
        0.33006930111794425,
        0.45771316133349194,
        0.5843689917649063,
        0.7248277689271266,
        0.8798264565500529,
        0.9758911275606239,
        1,
        0.9596437484362145,
        0.8843595823054808,
        0.7762550533119575,
        0.6378974013713614,
        0.4902092641829906,
        0.34974003449834606,
        0.23709517280240033,
        0.1533655650777773,
        0.10425916458771778,
        0.07210432776312349,
        0.04990384682016121,
        0.03128361138031443,
        0.023035971147449902,
        0.01416623174352829,
        0.0050473810108063654,
        0.00730744172169337,
        0.0003922410892856903
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC LX9 / prf-solomatov-pred-panasonic-dmc-lx9-5ca70bc86399@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC LX9 / prf-solomatov-pred-panasonic-dmc-lx9-5ca70bc86399@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000519368622642 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27526537; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.059199884551405804,
        0.14326687964470922,
        0.3303872325440858,
        0.5453132752046372,
        0.6844974979796934,
        0.7752944723042269,
        0.835579893243603,
        0.8318973541013293,
        0.7772149585143965,
        0.6655681714688334,
        0.5127474945359092,
        0.36064688605548806,
        0.2308479886853576,
        0.1423842962883417,
        0.10520856911170375,
        0.08192261624746794,
        0.07489877423946001,
        0.06971540666567072,
        0.060795209339639965,
        0.04557205726019888,
        0.031190120646124142,
        0.018971493330772197,
        0.0076004296473336196,
        0.000020207316295636453,
        0.00002835126870027276,
        0.000024270528136875002,
        0.0000236409393751289,
        0.00007278376634566974,
        0.00013064324073892766,
        0.00007893174650264616,
        0.0014072578503323645
      ],
      "range": 1
    }
  }
]
