[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC ZS40 / prf-solomatov-pred-panasonic-dmc-zs40-0fd512c25913@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC ZS40 / prf-solomatov-pred-panasonic-dmc-zs40-0fd512c25913@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26813745 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26813745; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.013751635215446405,
        0.02452311939268461,
        0.023674046277384977,
        0.0010201954258907138,
        0.00023677942040546744,
        0.009447782471266137,
        0.03654577158095596,
        0.06601909580329043,
        0.10756802900900266,
        0.1075358589410021,
        0.09273972360071299,
        0.0747236725045308,
        0.05326303356729916,
        0.011821334916103663,
        0.0013956654693329858,
        0.00004863727726209077,
        0.007624533611399676,
        0.24950123901006743,
        0.5889389937884469,
        0.7480216210007219,
        0.7304257946810488,
        0.6617509415413624,
        0.5708928014344882,
        0.495929680840927,
        0.4257901162258387,
        0.34822733639034753,
        0.2786706743127452,
        0.19210697722380818,
        0.11334399577530106,
        0.04442155692910483,
        0.03012349076937966
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC ZS40 / prf-solomatov-pred-panasonic-dmc-zs40-0fd512c25913@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC ZS40 / prf-solomatov-pred-panasonic-dmc-zs40-0fd512c25913@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26813745 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26813745; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.017806293003830687,
        0.030419980498807606,
        0.05996469721033,
        0.09627571978475964,
        0.13546685477914405,
        0.17047558257900938,
        0.22177098723061625,
        0.3123033876841896,
        0.42516873342384665,
        0.5397067436868666,
        0.6776361526523057,
        0.8440082129519767,
        0.9594398320712009,
        1,
        0.9824645531610747,
        0.9248574565022528,
        0.836523208526075,
        0.7041116785439707,
        0.556171321835126,
        0.41734723739634283,
        0.307484799307221,
        0.22170338384287613,
        0.16650796074923516,
        0.11803949802610565,
        0.07954139938304029,
        0.048669531242278914,
        0.031162834583531692,
        0.012242856788561239,
        0.006643019839265273,
        0.007527832460553346,
        0.0003643716123950608
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC ZS40 / prf-solomatov-pred-panasonic-dmc-zs40-0fd512c25913@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DMC ZS40 / prf-solomatov-pred-panasonic-dmc-zs40-0fd512c25913@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26813745 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26813745; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04920325004955481,
        0.11667340761240177,
        0.273236371868234,
        0.4602043466886106,
        0.5823697510362689,
        0.6642967254294393,
        0.7265323064719232,
        0.7359966688726248,
        0.6934625879376417,
        0.5993750593212548,
        0.4673052943555628,
        0.3397730156678972,
        0.22767617130691742,
        0.1505302112778353,
        0.11501683931133082,
        0.0904779917911504,
        0.08059878618223601,
        0.08311279532195148,
        0.08458517823601291,
        0.06611286114640084,
        0.038518472522208295,
        0.017789772745284184,
        0.005469395640183794,
        0.00001682136344624744,
        0.000009722949927360016,
        0.00003073490107405735,
        0.00007617462611060112,
        0.00005607019832552297,
        9.560470572089054e-7,
        0.00018940384493102325,
        0.001893074018567716
      ],
      "range": 1
    }
  }
]
