[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / PENTAX K 1 Mark II / prf-solomatov-pred-pentax-k-1-mark-ii-52276ba13ef9@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / PENTAX K 1 Mark II / prf-solomatov-pred-pentax-k-1-mark-ii-52276ba13ef9@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2803019 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2803019; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.00781651034117143,
        0.016889227650615284,
        0.019621097823453927,
        0.004269586114114817,
        0.01588422697099092,
        0.028533174409449243,
        0.04033321215446631,
        0.04577775605516766,
        0.05741163367069578,
        0.05494146133151434,
        0.048210490189328006,
        0.046033483897183716,
        0.05571590845442004,
        0.05606852111955003,
        0.050510346166044544,
        0.061720930182777925,
        0.11044023247791043,
        0.267764613796767,
        0.49440842177666294,
        0.6168843664634454,
        0.601512940154883,
        0.5452793220452663,
        0.4662061156203365,
        0.3955451247387192,
        0.3276955311398174,
        0.261633117720572,
        0.2023901800166178,
        0.13786728880539162,
        0.08010095900170494,
        0.03232705878911274,
        0.019454816396178548
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / PENTAX K 1 Mark II / prf-solomatov-pred-pentax-k-1-mark-ii-52276ba13ef9@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / PENTAX K 1 Mark II / prf-solomatov-pred-pentax-k-1-mark-ii-52276ba13ef9@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2803019 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2803019; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01781955206154507,
        0.025820570606192823,
        0.05019925658727251,
        0.08223215754156502,
        0.11403993337183943,
        0.13705762964860388,
        0.18283739068482946,
        0.27822198137080056,
        0.39416832351118564,
        0.5191341906708447,
        0.668120836854834,
        0.8433634948603631,
        0.9593257840920807,
        1,
        0.9737138421109525,
        0.9063896463063575,
        0.8006082013714498,
        0.6494137570954746,
        0.48337924216710626,
        0.3329890735667507,
        0.21016662748272488,
        0.12293898114854021,
        0.07660575615077886,
        0.04707963449409369,
        0.025992183071181466,
        0.010283602073335927,
        0.008077890303276575,
        0.000017812972370148045,
        0.00010648227500420084,
        0.003799921441845382,
        0.00038109743815507494
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / PENTAX K 1 Mark II / prf-solomatov-pred-pentax-k-1-mark-ii-52276ba13ef9@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / PENTAX K 1 Mark II / prf-solomatov-pred-pentax-k-1-mark-ii-52276ba13ef9@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2803019 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2803019; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.0472577852665287,
        0.11287008757343421,
        0.2639221139778218,
        0.4476266482674573,
        0.5848253615119984,
        0.6812572800969241,
        0.7600817190322292,
        0.7885189147843807,
        0.7682705325936071,
        0.6711196748933917,
        0.523467375711688,
        0.36396349792848354,
        0.21790762031937708,
        0.1111944906545407,
        0.06920896718859203,
        0.04124054100239777,
        0.03808097982924839,
        0.04213592915353053,
        0.04630214422378157,
        0.04136498896368523,
        0.029198168118018463,
        0.01596816503919524,
        0.0080344153928318,
        0.004816973770067202,
        0.002001036382557521,
        0.004023043368596503,
        0.001514551274893249,
        0.0014268677450991235,
        0.0018369893318596843,
        0.001013603546747275,
        0.0036957412703945277
      ],
      "range": 1
    }
  }
]
