[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / PENTAX K 50 / prf-solomatov-pred-pentax-k-50-0c33222f7420@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / PENTAX K 50 / prf-solomatov-pred-pentax-k-50-0c33222f7420@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26444438 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26444438; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.011088485979547003,
        0.021949263584274323,
        0.026612172283638623,
        0.0010163175712034418,
        0.012182180993976882,
        0.03034920991703435,
        0.051646020989366465,
        0.06708536592836649,
        0.09301205039789465,
        0.08258416382303152,
        0.06127475652914235,
        0.04086081163834906,
        0.02937227102349462,
        0.0032677273383537216,
        0.000020308153268373487,
        0.0000063964808025037255,
        0.016229696392110884,
        0.22235473485955726,
        0.5528518322075894,
        0.726308118175928,
        0.7025407006191624,
        0.6427776986601115,
        0.5576546569074375,
        0.4880444046494768,
        0.4215513296217526,
        0.3494332154080946,
        0.2807456524506212,
        0.1918479908705188,
        0.11397665928842958,
        0.04561230985510073,
        0.028051079399002546
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / PENTAX K 50 / prf-solomatov-pred-pentax-k-50-0c33222f7420@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / PENTAX K 50 / prf-solomatov-pred-pentax-k-50-0c33222f7420@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26444438 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26444438; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.0179127546594108,
        0.030127685073133337,
        0.06630547414167016,
        0.11157198349233212,
        0.16540598064515497,
        0.20348220294944444,
        0.24966070369882695,
        0.33051150491456843,
        0.4270747217240919,
        0.5357804540977578,
        0.6724185252112374,
        0.8408129906182918,
        0.9590930236445184,
        1,
        0.9825429831407272,
        0.9225554727236026,
        0.8301108535564266,
        0.6952562954826267,
        0.5438974728825774,
        0.4043173464302777,
        0.2903394468054114,
        0.20031949251483433,
        0.1460489650035293,
        0.10192590971303683,
        0.06882278231815704,
        0.044354434758643764,
        0.030935639471710467,
        0.016192811509172553,
        0.007213667010053306,
        0.006476515779991241,
        0.0014821065208494885
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / PENTAX K 50 / prf-solomatov-pred-pentax-k-50-0c33222f7420@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / PENTAX K 50 / prf-solomatov-pred-pentax-k-50-0c33222f7420@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26444438 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26444438; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04913245651127092,
        0.12072872185825996,
        0.2841310524352985,
        0.47131877032138103,
        0.6040055379509295,
        0.7046713566005828,
        0.7883845744802744,
        0.8213218598179323,
        0.7986134551242874,
        0.688938331758081,
        0.5313531336910999,
        0.36620040856984754,
        0.21419823707351998,
        0.10906183750246462,
        0.06528071422807323,
        0.040395995558688,
        0.04335392947280634,
        0.048438877770818956,
        0.043623649706603713,
        0.03355523191682123,
        0.029741093382283264,
        0.026729171933999887,
        0.020192306601486482,
        0.007406342309108631,
        0.000011148795826177135,
        0.00002886590367320342,
        0.00001675946374810461,
        0.00003157624298916846,
        0.00005730956732754162,
        0.000128933755370411,
        0.000031680941754179084
      ],
      "range": 1
    }
  }
]
