[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / PENTAX K 70 / prf-solomatov-pred-pentax-k-70-32a51d34c153@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / PENTAX K 70 / prf-solomatov-pred-pentax-k-70-32a51d34c153@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.28094238 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28094238; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.008209775969008308,
        0.014528460960571346,
        0.026110033665978055,
        0.019142451914873078,
        0.04638817753305856,
        0.05833944312709247,
        0.06062023109507366,
        0.04526845326789073,
        0.03256595177986319,
        0.01964487059588518,
        0.0024787406584937453,
        0.0000017211732170845852,
        0.00016755734040553087,
        0.0016587582834601176,
        0.0008841319348116863,
        0.011937577733911131,
        0.05802809102706398,
        0.21452608182503474,
        0.435617759057925,
        0.5746269395169216,
        0.5732186792181372,
        0.5304942244740719,
        0.45875385550588704,
        0.40664373954545413,
        0.3502915793622878,
        0.3001677069867494,
        0.23699717358413497,
        0.1708839976368108,
        0.10190116208170516,
        0.04453351608966935,
        0.029573523225652182
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / PENTAX K 70 / prf-solomatov-pred-pentax-k-70-32a51d34c153@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / PENTAX K 70 / prf-solomatov-pred-pentax-k-70-32a51d34c153@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.28094238 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28094238; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.014386068773248096,
        0.02224388965452631,
        0.041851087044966304,
        0.07534399046523348,
        0.09425661233452924,
        0.09991567309994313,
        0.13125680077174545,
        0.2200421773318785,
        0.3279534045379697,
        0.46107561272884495,
        0.6264417636100328,
        0.815979063037766,
        0.9455630012104261,
        1,
        0.9824006260643197,
        0.9204236114181136,
        0.8165094208997589,
        0.6503951094882873,
        0.4582427186670804,
        0.3026646246821145,
        0.19336144301190872,
        0.11820451225621426,
        0.08041825160020358,
        0.0432617321744053,
        0.010464106554518404,
        0.000011244226663132847,
        0.000018253070255900872,
        0.00003915558058559908,
        0.000007984593495648467,
        0.000015860978325875932,
        0.0000019281558731010967
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / PENTAX K 70 / prf-solomatov-pred-pentax-k-70-32a51d34c153@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / PENTAX K 70 / prf-solomatov-pred-pentax-k-70-32a51d34c153@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.28094238 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28094238; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04795129520864741,
        0.11399681671380445,
        0.27202570861683456,
        0.45383658385751563,
        0.5993868208847665,
        0.7196182719032992,
        0.811626853876585,
        0.8434114497072318,
        0.8200020231906628,
        0.6942804072493441,
        0.5223226556278194,
        0.3470755960706249,
        0.2036690939971392,
        0.10258802890471705,
        0.07181053994060989,
        0.049675364037280526,
        0.05028041693104472,
        0.05618127104924505,
        0.05683883649024402,
        0.039572929509602645,
        0.00795820303081365,
        0.00001965247998539772,
        0.000019738441384315175,
        0.0000025634993196825627,
        0.000008468747933295077,
        0.00010932367697604042,
        0.00159977739919481,
        0.0035278376299083107,
        0.0020175265120200092,
        0.0010872047143617137,
        0.002728571104153101
      ],
      "range": 1
    }
  }
]
