    "model": "ESTIMATED PHOTON-RESPONSE MODEL / PENTAX K S2 / prf-solomatov-pred-pentax-k-s2-6eaab2e66505@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / PENTAX K S2 / prf-solomatov-pred-pentax-k-s2-6eaab2e66505@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00050449754717 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2673837; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.014188320716633064,
        0.025707565825039757,
        0.03168439587005491,
        0.004307419010800358,
        0.01959044753085003,
        0.0432590452513664,
        0.06903523890459907,
        0.08793303406303377,
        0.11791367206253285,
        0.11007117288521234,
        0.0897221884505301,
        0.06306295065268142,
        0.04503695754884777,
        0.017176799857283747,
        0.00007088622725402567,
        0.00020231694724574733,
        0.03108325674462793,
        0.20900409372275439,
        0.46659144865986396,
        0.5977222119754102,
        0.5769761121065595,
        0.523519937949796,
        0.44666827351540606,
        0.38458940739528524,
        0.3253933374818659,
        0.26652966665794975,
        0.21045424722236358,
        0.1460346434116294,
        0.08672432416961313,
        0.03493812249500668,
        0.026365465861552948
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / PENTAX K S2 / prf-solomatov-pred-pentax-k-s2-6eaab2e66505@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / PENTAX K S2 / prf-solomatov-pred-pentax-k-s2-6eaab2e66505@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00050449754717 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2673837; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.023116810112209535,
        0.03596960899809305,
        0.07373533890844969,
        0.1242995141439063,
        0.17478620883499155,
        0.20708894870305608,
        0.2564661928353052,
        0.3530713494773019,
        0.46255417324117615,
        0.580017504157997,
        0.7187157242569386,
        0.8820413664619311,
        0.9802200207474818,
        1,
        0.9615342421147338,
        0.8850295124061924,
        0.7782751629159572,
        0.6315623702317432,
        0.47222067530410544,
        0.33507433071662146,
        0.2305997666773754,
        0.15396940770148962,
        0.1082548599030942,
        0.07031106281715799,
        0.041514662320945514,
        0.02095222293194847,
        0.010232623255144822,
        0.0014321511577646208,
        0.00009970807236500779,
        0.002052304831671825,
        0.000029769527435132145
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / PENTAX K S2 / prf-solomatov-pred-pentax-k-s2-6eaab2e66505@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / PENTAX K S2 / prf-solomatov-pred-pentax-k-s2-6eaab2e66505@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00050449754717 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2673837; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06302807155036003,
        0.1461334668985833,
        0.3364340298764873,
        0.5600130668416403,
        0.7170177215875028,
        0.8243464371405005,
        0.907465652153262,
        0.9374727484422557,
        0.9101498247961014,
        0.7897556651236957,
        0.6148549616150871,
        0.43274253808437896,
        0.2653510652122198,
        0.1419884981769644,
        0.0827073103115416,
        0.03609474977515288,
        0.022410731215638267,
        0.031033103429804653,
        0.05387947319358556,
        0.046584251617888574,
        0.018293944245666435,
        0.00023669176800427468,
        0.00006375000782673713,
        0.0016396022264680676,
        0.01181247938356003,
        0.021056336573764448,
        0.02502029463480928,
        0.019815751268821975,
        0.012256231686787895,
        0.004201838558519873,
        0.005668773136561001
      ],