[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Pentax K10D / prf-solomatov-pred-pentax-k10d-1ebf37edda94@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Pentax K10D / prf-solomatov-pred-pentax-k10d-1ebf37edda94@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26926148 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26926148; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.008658536304561648,
        0.016191844448006452,
        0.021421183601902507,
        0.0012605012049996904,
        0.01607556454046082,
        0.02483211375054464,
        0.03089161880860196,
        0.02713658671117755,
        0.02714028571780858,
        0.016267701195135674,
        0.00004537387598107238,
        0.000008816599388817146,
        0.000016651785097519335,
        0.0009896208696468579,
        0.0005846099486640273,
        0.010620043758208565,
        0.05879101979235946,
        0.22065523445834137,
        0.47453976706954143,
        0.6300972942732098,
        0.6225709299376948,
        0.5753770647030537,
        0.49953357606145515,
        0.4385550989320864,
        0.3744833089382113,
        0.31221394905799377,
        0.2509568988479154,
        0.17552401479780916,
        0.10300692843254074,
        0.04033097493187663,
        0.026576523311095224
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Pentax K10D / prf-solomatov-pred-pentax-k10d-1ebf37edda94@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Pentax K10D / prf-solomatov-pred-pentax-k10d-1ebf37edda94@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26926148 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26926148; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.015960927645499088,
        0.025543819710119695,
        0.055403509629375874,
        0.0980549650102198,
        0.13679172379205523,
        0.15722672251522943,
        0.19059178089639853,
        0.2643784398719044,
        0.3548533938088731,
        0.4694277101945663,
        0.6231092913847165,
        0.8123332383079823,
        0.9457553304691039,
        1,
        0.9830060356200968,
        0.9190206486274977,
        0.8155114500596223,
        0.6588326336169585,
        0.47973256330612163,
        0.3222487895409325,
        0.20521739685899373,
        0.12007811143279759,
        0.07853251790787155,
        0.0463267267193213,
        0.02245561080626906,
        0.0017358969058626581,
        0.00001809577292674764,
        0.0000392955891797074,
        0.000016713894612775658,
        0.0005735422682813747,
        0.0002739450514793278
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Pentax K10D / prf-solomatov-pred-pentax-k10d-1ebf37edda94@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Pentax K10D / prf-solomatov-pred-pentax-k10d-1ebf37edda94@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26926148 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26926148; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.046321018513305355,
        0.11476062599076556,
        0.27976621461042256,
        0.4701586725290227,
        0.6132050897142807,
        0.7352885752540615,
        0.8434013658396292,
        0.9028866661506875,
        0.9143218331860912,
        0.8066233610540952,
        0.620989604602931,
        0.40625521333389386,
        0.20869774614623673,
        0.0629035946768175,
        0.011075633989681703,
        0.0000015271144613778398,
        0.0010156517746244282,
        0.020576961101157136,
        0.027619411436050935,
        0.03054849880495346,
        0.03326357709985105,
        0.03292229545793182,
        0.019993015710973585,
        0.0019332962145198042,
        0.000027878087129284144,
        0.000008629809581377924,
        0.000010143185724151854,
        0.000014498605593343689,
        0.00002223799111555058,
        0.00007456044213973718,
        0.00016482367994114866
      ],
      "range": 1
    }
  }
]
