    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Phase One IQ3 100MP / prf-solomatov-pred-phase-one-iq3-100mp-1048636c2b00@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Phase One IQ3 100MP / prf-solomatov-pred-phase-one-iq3-100mp-1048636c2b00@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26743498 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26743498; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.011403797289344873,
        0.01645882000925982,
        0.014019078581268614,
        0.0000010327684882508638,
        0.00003716637965609435,
        0.0000013623964598797062,
        0.000006672897464647295,
        0.02599076231538597,
        0.06864462906086556,
        0.08642316723115279,
        0.10030473949219358,
        0.11208049522915814,
        0.12148828100198412,
        0.12923726357711324,
        0.13136550050408516,
        0.1468413593464849,
        0.1931231808195024,
        0.3009497860003205,
        0.44480828947656736,
        0.5229832312885921,
        0.4970202476878679,
        0.43905778518576744,
        0.36980850448209884,
        0.30439346416089624,
        0.24188129765223682,
        0.18021591640704596,
        0.1334928886266112,
        0.08471024620638631,
        0.046747114008795713,
        0.021575778905212777,
        0.009666351424933268
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Phase One IQ3 100MP / prf-solomatov-pred-phase-one-iq3-100mp-1048636c2b00@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Phase One IQ3 100MP / prf-solomatov-pred-phase-one-iq3-100mp-1048636c2b00@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26743498 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26743498; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.017010821471447005,
        0.029134747070110278,
        0.056351891588751785,
        0.09042407242313627,
        0.12721176190190228,
        0.15356169937081532,
        0.1914712129280919,
        0.26984274831961025,
        0.3674910813835946,
        0.4767329614099098,
        0.6194079398289634,
        0.7981913211203711,
        0.9392037645935472,
        1,
        0.989343465839809,
        0.93274245575504,
        0.8476017609962616,
        0.7486570380583721,
        0.6499301624641624,
        0.5151884394479734,
        0.370079897551173,
        0.24906558596037062,
        0.17831979197336117,
        0.1413691731724848,
        0.11793075834731867,
        0.09501360293257075,
        0.08489776094361329,
        0.05672385489736608,
        0.030668804058466847,
        0.017311856511814574,
        0.00757294913328092
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Phase One IQ3 100MP / prf-solomatov-pred-phase-one-iq3-100mp-1048636c2b00@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Phase One IQ3 100MP / prf-solomatov-pred-phase-one-iq3-100mp-1048636c2b00@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26743498 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26743498; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.052009022903436196,
        0.12411575703372835,
        0.28717292704193,
        0.47657711044381706,
        0.6196173365204507,
        0.7356334612622478,
        0.8339080026105785,
        0.8930765152711138,
        0.9077821831684098,
        0.8213930728134368,
        0.6561428501237946,
        0.4535846993538392,
        0.25056630213444775,
        0.09821511008021463,
        0.03820713356195962,
        0.0011376383149279874,
        0.0006775780415860334,
        0.000016710816961939685,
        0.000030219909901090725,
        0.000022939441205484787,
        0.028493686203652193,
        0.05118352131796671,
        0.04424418974660682,
        0.01672537003199806,
        0.000043709618689372646,
        0.000038669702071135195,
        0.00010880967029817865,
        0.00003968973131338316,
        0.000051124564931633104,
        0.00009896662732750967,
        0.002975909882843299
      ],
      "range": 1
    }
  }
]