[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Phase One IQ3 50MP / prf-solomatov-pred-phase-one-iq3-50mp-1b126bb34193@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Phase One IQ3 50MP / prf-solomatov-pred-phase-one-iq3-50mp-1b126bb34193@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27897972 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27897972; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.011346814026481926,
        0.019414194336419867,
        0.01544222999435228,
        0.0003615712496951391,
        0.00022968415051818105,
        0.000051726896134242305,
        0.00036115238053862844,
        0.012954468518356818,
        0.049208028454541426,
        0.057201290473730494,
        0.06687772860335511,
        0.08818776504614745,
        0.11132671579138442,
        0.11947810399981762,
        0.11567453720291926,
        0.13229070915979127,
        0.1936831609121982,
        0.4021375102104196,
        0.6577968104634989,
        0.73328699304738,
        0.6682654567149182,
        0.5823708977842548,
        0.4866707515514031,
        0.4022571963295397,
        0.33345843203226383,
        0.2557679102982826,
        0.19423091398901685,
        0.12511006176362927,
        0.06701335136475153,
        0.02985218782211123,
        0.017911617374911697
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Phase One IQ3 50MP / prf-solomatov-pred-phase-one-iq3-50mp-1b126bb34193@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Phase One IQ3 50MP / prf-solomatov-pred-phase-one-iq3-50mp-1b126bb34193@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27897972 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27897972; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01860553734873632,
        0.027996235712043873,
        0.051664361122736806,
        0.08013321541795225,
        0.10841433205252339,
        0.1395685069868161,
        0.19681406232682433,
        0.30540313109497713,
        0.4445632105444797,
        0.5770113684249164,
        0.7227666584510157,
        0.8776848725778348,
        0.9769266382516981,
        1,
        0.9632167528162979,
        0.88593285562119,
        0.7759877312945902,
        0.644114848204737,
        0.5081054278784136,
        0.3605731986540097,
        0.21803199888508026,
        0.11876723512375739,
        0.07111004341104078,
        0.05447878433600837,
        0.04716172200617307,
        0.043538028498989106,
        0.050180701306890695,
        0.03297381616126076,
        0.019050470765401874,
        0.014423937338527692,
        0.009591054862339098
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Phase One IQ3 50MP / prf-solomatov-pred-phase-one-iq3-50mp-1b126bb34193@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Phase One IQ3 50MP / prf-solomatov-pred-phase-one-iq3-50mp-1b126bb34193@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27897972 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27897972; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04100723163676557,
        0.10834538438851397,
        0.2572761202857326,
        0.4382832343512281,
        0.554606478205656,
        0.629115514202968,
        0.6788560473141202,
        0.6713371853696032,
        0.6167440056216273,
        0.5248403719094707,
        0.4110204318794212,
        0.3096478482378576,
        0.22766758816734062,
        0.18420629284451215,
        0.17428195139058852,
        0.17332888569821492,
        0.1718610155605576,
        0.1479107047637728,
        0.10817263348031177,
        0.08066956623226951,
        0.07495623696231396,
        0.06292410071957918,
        0.0465996202161218,
        0.022726734402056182,
        0.0025921554441304907,
        0.00015932812607310668,
        0.000012432066388194813,
        0.0000038447909403593925,
        0.000037536577927599895,
        0.0000144604177680012,
        0.0008313380986976402
      ],
      "range": 1
    }
  }
]
