    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Phase One IQ3 60MP / prf-solomatov-pred-phase-one-iq3-60mp-16ec13304b0a@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Phase One IQ3 60MP / prf-solomatov-pred-phase-one-iq3-60mp-16ec13304b0a@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.28489235 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28489235; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.014119758919465545,
        0.023011190016158735,
        0.020119816134059058,
        0.0031374117276227317,
        0.004121110658113494,
        0.007844484065647955,
        0.010186820039218322,
        0.014441556609013896,
        0.05322084289030576,
        0.0562723533994507,
        0.06438209379788541,
        0.09039841540146654,
        0.12270184510043881,
        0.14930646610904083,
        0.15703306178632032,
        0.18203887889583556,
        0.24635459674505125,
        0.41454451128645603,
        0.6342014448615415,
        0.6981071973326064,
        0.6229307666562475,
        0.522850332766043,
        0.42555389781438496,
        0.3590579389021853,
        0.3042976057447664,
        0.23258873044502595,
        0.17862077728657857,
        0.11543302935301701,
        0.061796875205669795,
        0.030043186487808463,
        0.011464891212417602
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Phase One IQ3 60MP / prf-solomatov-pred-phase-one-iq3-60mp-16ec13304b0a@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Phase One IQ3 60MP / prf-solomatov-pred-phase-one-iq3-60mp-16ec13304b0a@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.28489235 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28489235; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.016997088549411735,
        0.02754631354615173,
        0.05097598794772833,
        0.0839446022330891,
        0.11799027597617134,
        0.1473180308281356,
        0.1946354965305316,
        0.288736429742673,
        0.41466696104686557,
        0.5410687229755379,
        0.6873999951209641,
        0.854901684794274,
        0.9680097061223301,
        1,
        0.9657197183427354,
        0.8862923135703713,
        0.7776799552532737,
        0.6566036258958866,
        0.5399069859194183,
        0.38813781416033105,
        0.22876932286879587,
        0.10903391754815459,
        0.05615993198834576,
        0.05045573880800941,
        0.06154629283657494,
        0.06777412591106781,
        0.08090155807974485,
        0.05880417989461634,
        0.033691104727803324,
        0.02234745510014572,
        0.010052277641010717
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Phase One IQ3 60MP / prf-solomatov-pred-phase-one-iq3-60mp-16ec13304b0a@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Phase One IQ3 60MP / prf-solomatov-pred-phase-one-iq3-60mp-16ec13304b0a@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.28489235 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28489235; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.0438680048797379,
        0.11062493605040641,
        0.259780545177854,
        0.4404886968709409,
        0.555689894797105,
        0.6264158023197183,
        0.6741605381822291,
        0.6641500201742868,
        0.6058576862453484,
        0.5039403128936245,
        0.3784131795746709,
        0.2661033369270884,
        0.17998266713725378,
        0.13445877714863175,
        0.13509072110921896,
        0.14306579309693643,
        0.15271838643613983,
        0.1275956339297984,
        0.07645813234367296,
        0.053316103433454776,
        0.06391857836828542,
        0.06574670046422798,
        0.052648486349317555,
        0.020085896655350696,
        0.00006149264801248612,
        0.000033138134456751824,
        0.00005300229016328448,
        0.00005524096733380169,
        0.00000934679713232033,
        0.00003241466820713157,
        0.0007732838386148312
      ],
      "range": 1
    }
  }
]