[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Pixel 2 XL Google google / prf-solomatov-pred-pixel-2-xl-google-google-0dfd3d5cc0ac@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Pixel 2 XL Google google / prf-solomatov-pred-pixel-2-xl-google-google-0dfd3d5cc0ac@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26293063 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26293063; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.013603816337411886,
        0.023521998939416075,
        0.025163434172732178,
        0.0009279809278972176,
        0.0000612335770845717,
        0.013041793190850377,
        0.04390333298178306,
        0.07403173985472898,
        0.11621105536467927,
        0.11813508757043635,
        0.0994856628153213,
        0.0774386917188005,
        0.04984006237690908,
        0.0035560195478176126,
        0.002107921203398782,
        0.0032311904474575668,
        0.006922496629624323,
        0.2671211642401648,
        0.6265241139839813,
        0.7840580992788858,
        0.7576030605487082,
        0.6801260469348892,
        0.5827215718457754,
        0.5031548815746572,
        0.43709897930111835,
        0.36179389217604657,
        0.28162017487274116,
        0.19799393475001373,
        0.10781674618890923,
        0.043772983010765994,
        0.03270374394949725
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Pixel 2 XL Google google / prf-solomatov-pred-pixel-2-xl-google-google-0dfd3d5cc0ac@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Pixel 2 XL Google google / prf-solomatov-pred-pixel-2-xl-google-google-0dfd3d5cc0ac@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26293063 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26293063; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.016724905728936947,
        0.030046678091479873,
        0.06017869428145363,
        0.09731369068715957,
        0.13520590963479606,
        0.16881512055099857,
        0.2244283330549963,
        0.32266522162138356,
        0.44674060987112835,
        0.5675054671264431,
        0.7020780348033243,
        0.8582488088207905,
        0.9640951683719772,
        1,
        0.9852521176403068,
        0.9300251553042718,
        0.8449614257570524,
        0.710351623924531,
        0.5578524647356604,
        0.41699787887017953,
        0.30765148967239003,
        0.22245308581963233,
        0.16686433984507623,
        0.11516297283431755,
        0.0731835009104873,
        0.04025215890594413,
        0.024404662933337207,
        0.007441372654072293,
        0.003150694804937713,
        0.005812230016715816,
        0.00017662548482845077
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Pixel 2 XL Google google / prf-solomatov-pred-pixel-2-xl-google-google-0dfd3d5cc0ac@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Pixel 2 XL Google google / prf-solomatov-pred-pixel-2-xl-google-google-0dfd3d5cc0ac@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26293063 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26293063; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04671681271976567,
        0.11207219181728656,
        0.2630903824328113,
        0.45132147593454597,
        0.5793931273811652,
        0.6645173671854055,
        0.7302337502481168,
        0.7439774894237313,
        0.7091092049640622,
        0.6229127812153343,
        0.5014575897832824,
        0.38179735848957574,
        0.2721848154397226,
        0.19149320868397873,
        0.14731421744206827,
        0.11137110575515678,
        0.0918994869483255,
        0.09220958394995668,
        0.0985035900914245,
        0.07436141616516874,
        0.03793577416218111,
        0.008841163922210205,
        0.0009104671068562837,
        0.0002598253767543173,
        0.00440366951541553,
        0.008844589920923249,
        0.012876445775830683,
        0.011505340401002349,
        0.005926114047648234,
        0.00023707146634076068,
        0.002414723609797763
      ],
      "range": 1
    }
  }
]
