[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Pixii Camera (A1571) / prf-solomatov-pred-pixii-camera-a1571-1567dab3da78@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Pixii Camera (A1571) / prf-solomatov-pred-pixii-camera-a1571-1567dab3da78@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000502281531915 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26228034; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01190769044841852,
        0.022102263036154018,
        0.027636015573129297,
        0.005850984375525066,
        0.014949433417460611,
        0.03340417638873451,
        0.05324773371401059,
        0.0685940223741606,
        0.08959998289224816,
        0.08007193278218942,
        0.05261083340901636,
        0.021564242553415207,
        0.006168116797037842,
        0.0013594939010438964,
        0.002223943854091768,
        0.0036041286762540322,
        0.0037561084943316166,
        0.14212413114939124,
        0.4260601362649641,
        0.5980583098936141,
        0.5803437875873518,
        0.5264919769459478,
        0.4557486800053749,
        0.41428375551012214,
        0.367050469031058,
        0.3255237834288695,
        0.2704068435854357,
        0.19466284548836058,
        0.11773886767859452,
        0.0473640977869636,
        0.036707905199801244
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Pixii Camera (A1571) / prf-solomatov-pred-pixii-camera-a1571-1567dab3da78@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Pixii Camera (A1571) / prf-solomatov-pred-pixii-camera-a1571-1567dab3da78@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000502281531915 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26228034; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.020415005028967394,
        0.035236112928568965,
        0.07684038669651258,
        0.14392609325898967,
        0.20626043410996028,
        0.2277850378882012,
        0.25541508985927264,
        0.3213521178594763,
        0.4045909091897489,
        0.5251853416818048,
        0.6740569550890169,
        0.8485944759074959,
        0.9553255960194416,
        0.9852414126219282,
        0.9493425338660816,
        0.8776004350161541,
        0.7787862059752344,
        0.6356374055947935,
        0.4686383663248209,
        0.33751839051492966,
        0.24945760900727376,
        0.18482770136835647,
        0.1392064694138999,
        0.0916448472836024,
        0.050628447910580965,
        0.018479725065737355,
        0.0019691987838919255,
        0.00018217520054365533,
        0.000004845691154901924,
        0.0005698188367980147,
        0.00030779740081344565
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Pixii Camera (A1571) / prf-solomatov-pred-pixii-camera-a1571-1567dab3da78@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Pixii Camera (A1571) / prf-solomatov-pred-pixii-camera-a1571-1567dab3da78@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000502281531915 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26228034; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06739497741624262,
        0.16326118974587234,
        0.36453536377165713,
        0.5754012909027989,
        0.7344301121560778,
        0.8642541752553718,
        0.9643527706660622,
        1,
        0.9695988253373657,
        0.804586457373118,
        0.5917361501763528,
        0.3744257459316023,
        0.19856332747784824,
        0.07267311999024643,
        0.028738336985823607,
        0.0004301266862937287,
        0.0012047577563156435,
        0.019128125563163734,
        0.046988648144070784,
        0.041122376311043235,
        0.013801333633693269,
        0.0003257070565994492,
        0.0000598667403714361,
        0.00003775167953374869,
        0.00004100479562523468,
        0.005038603913345773,
        0.007972088306745078,
        0.008332098609670678,
        0.00476925230320248,
        0.0013977960572249303,
        0.0015796806733994544
      ],
      "range": 1
    }
  }
]
