    "model": "ESTIMATED PHOTON-RESPONSE MODEL / RICOH GR A12 50mm F2 / prf-solomatov-pred-ricoh-gr-a12-50mm-f2-2135b0e4253b@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / RICOH GR A12 50mm F2 / prf-solomatov-pred-ricoh-gr-a12-50mm-f2-2135b0e4253b@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27499047 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27499047; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.011326347054863394,
        0.01936216444155319,
        0.028722759010521348,
        0.006689713283518517,
        0.028754974672395014,
        0.046110608851281286,
        0.06375161291953137,
        0.07125092371382907,
        0.0859567969755461,
        0.08623170104767632,
        0.07653903788011272,
        0.07335833129053528,
        0.07352425704061671,
        0.059649376212928394,
        0.03296844068814457,
        0.03313127542201735,
        0.0702348121373079,
        0.2579103777669095,
        0.562381561804669,
        0.7098950010885833,
        0.6746348700738611,
        0.6070857655539845,
        0.5189736211585806,
        0.44321190476164507,
        0.36981076107837485,
        0.2984143050484622,
        0.2318578531103278,
        0.1539938674965718,
        0.08759432281416879,
        0.033328133153123454,
        0.02474212906359991
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / RICOH GR A12 50mm F2 / prf-solomatov-pred-ricoh-gr-a12-50mm-f2-2135b0e4253b@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / RICOH GR A12 50mm F2 / prf-solomatov-pred-ricoh-gr-a12-50mm-f2-2135b0e4253b@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27499047 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27499047; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01762825817200138,
        0.027607750552228232,
        0.054299745369357715,
        0.08659564820555418,
        0.12172661838062972,
        0.15336485660757626,
        0.2064003999847704,
        0.31156159702552605,
        0.438303421933131,
        0.5634973095613095,
        0.7051846196706381,
        0.866301912208085,
        0.9713118421885675,
        1,
        0.9736494868349437,
        0.9074941397060051,
        0.8122082557988283,
        0.674056995502426,
        0.521322138909032,
        0.3770297021565875,
        0.25910337910982884,
        0.1701780938081236,
        0.12109612380385401,
        0.08362677804798108,
        0.05429297240737107,
        0.03160881175264001,
        0.023703283244688445,
        0.012313115796340143,
        0.006759790984756672,
        0.007730722450127091,
        0.0009103023097491343
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / RICOH GR A12 50mm F2 / prf-solomatov-pred-ricoh-gr-a12-50mm-f2-2135b0e4253b@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / RICOH GR A12 50mm F2 / prf-solomatov-pred-ricoh-gr-a12-50mm-f2-2135b0e4253b@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27499047 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27499047; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04405537762817745,
        0.10712213045055707,
        0.2566385664201381,
        0.44046282767544637,
        0.571150192950323,
        0.654673523777024,
        0.7165973424460855,
        0.7274021532455288,
        0.6884717495846311,
        0.5972761528790435,
        0.4703492815587391,
        0.349573677953276,
        0.24186663632379699,
        0.16346125740284745,
        0.12466456383015746,
        0.09274099571523334,
        0.07290663563722773,
        0.05970874554307282,
        0.05319859630044634,
        0.033127395287553055,
        0.004115165881930382,
        0.000023996339582240794,
        0.00005639536890132957,
        0.00002145653374824226,
        0.000023744648314539774,
        0.0012888777563818848,
        0.006876653943680303,
        0.005678858252796907,
        0.003577976356780655,
        0.0008954596862938559,
        0.0007236647146353836
      ],
      "range": 1
    }
  }
]