    "model": "ESTIMATED PHOTON-RESPONSE MODEL / RICOH GR A12 50mm F2 / prf-solomatov-pred-ricoh-gr-a12-50mm-f2-2135b0e4253b@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / RICOH GR A12 50mm F2 / prf-solomatov-pred-ricoh-gr-a12-50mm-f2-2135b0e4253b@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000518849943396 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27499047; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.015007409847693996,
        0.025029139400056563,
        0.03624538637041979,
        0.00824546055875538,
        0.03463667403720308,
        0.054308050424842394,
        0.07345294532032962,
        0.08034678631559448,
        0.09491062999383214,
        0.0932710235821805,
        0.08113138015291949,
        0.07623512859604645,
        0.07493818506062858,
        0.05964937621292839,
        0.03235791400873449,
        0.031926501770307626,
        0.06647223291566638,
        0.2398114038885299,
        0.5139003926835769,
        0.637702289113473,
        0.5959274685652439,
        0.5274679602354292,
        0.44363874066781883,
        0.37286080876773314,
        0.30624953651802916,
        0.24332243334720766,
        0.18618888204314202,
        0.12181604443758665,
        0.06827204572280803,
        0.025599870392978886,
        0.01873332629101136
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / RICOH GR A12 50mm F2 / prf-solomatov-pred-ricoh-gr-a12-50mm-f2-2135b0e4253b@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / RICOH GR A12 50mm F2 / prf-solomatov-pred-ricoh-gr-a12-50mm-f2-2135b0e4253b@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000518849943396 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27499047; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.023357442077901826,
        0.03568806778702673,
        0.06852110725180853,
        0.10673417104405514,
        0.1466252448675767,
        0.1806297200044787,
        0.23780915650419193,
        0.3513354179224017,
        0.4839600283844988,
        0.6094970899336613,
        0.7474956968508764,
        0.900274536216245,
        0.9899909160768091,
        1,
        0.9556189407824447,
        0.8744943528076049,
        0.7686970992381766,
        0.6267547502040101,
        0.4763805752099775,
        0.33868769854744296,
        0.22887465154701545,
        0.14785965527591066,
        0.10351765421942359,
        0.07035268629433329,
        0.04496136777485416,
        0.025773338813691087,
        0.019034454726795266,
        0.009740225928448172,
        0.005268660620472112,
        0.005938091157343997,
        0.0006892288916672017
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / RICOH GR A12 50mm F2 / prf-solomatov-pred-ricoh-gr-a12-50mm-f2-2135b0e4253b@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / RICOH GR A12 50mm F2 / prf-solomatov-pred-ricoh-gr-a12-50mm-f2-2135b0e4253b@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000518849943396 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27499047; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.05837337535733511,
        0.13847494911901279,
        0.3238534290539838,
        0.5428960434139223,
        0.6879763687810708,
        0.7710599280040505,
        0.8256447641226637,
        0.8202620025960219,
        0.7601875568330302,
        0.6460333898487612,
        0.49857023845226345,
        0.36328244963771816,
        0.2465179177915623,
        0.16346125740284742,
        0.12235596079626565,
        0.08936859587104304,
        0.06900092301380481,
        0.055518658136541395,
        0.04861251041247683,
        0.029758507631191724,
        0.00363506319570517,
        0.00002084927865342233,
        0.00004820894438339463,
        0.000018050734740584754,
        0.00001966353688547825,
        0.0010509310936652292,
        0.005522161500228122,
        0.004492231155197553,
        0.0027887168663143337,
        0.0006878168604865849,
        0.0005479175696525046
      ],
      "range": 1
    }
  }
]