[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Ricoh GR DIGITAL 3 / prf-solomatov-pred-ricoh-gr-digital-3-c0b6b5958be2@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Ricoh GR DIGITAL 3 / prf-solomatov-pred-ricoh-gr-digital-3-c0b6b5958be2@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26866862 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26866862; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01437543580638483,
        0.022683460390722218,
        0.028624295609959955,
        0.0002642620116930663,
        0.015696044815356552,
        0.031960811054152875,
        0.056345651754938844,
        0.07744994186518693,
        0.10800888469967203,
        0.10911241513802392,
        0.09845869979158711,
        0.08572896231796626,
        0.07407231629804775,
        0.046511993101390106,
        0.008806078655557168,
        0.00010285161326246437,
        0.04162526498256476,
        0.2538811194251118,
        0.5862758739744149,
        0.747624229431781,
        0.7130145306883997,
        0.639211010202829,
        0.54761378533898,
        0.4711280386968898,
        0.4016879604324465,
        0.3233987058108982,
        0.25420452898444185,
        0.17527249739846804,
        0.09907703028362597,
        0.03819250644157847,
        0.02985164772871502
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Ricoh GR DIGITAL 3 / prf-solomatov-pred-ricoh-gr-digital-3-c0b6b5958be2@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Ricoh GR DIGITAL 3 / prf-solomatov-pred-ricoh-gr-digital-3-c0b6b5958be2@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26866862 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26866862; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.018783966657512884,
        0.031203402168813014,
        0.061304837163342694,
        0.0989447074243356,
        0.14205184438733484,
        0.18268836159578292,
        0.24137575128796207,
        0.3450076343117406,
        0.47146622482372513,
        0.5925186201499825,
        0.7288146267323663,
        0.8795767812407715,
        0.9746339189146837,
        1,
        0.9729433977068107,
        0.906907736377996,
        0.8125622188404436,
        0.6838812437418259,
        0.5388466654572461,
        0.39962621611708876,
        0.28112479231850745,
        0.19320284966662649,
        0.1403770190951217,
        0.09730355186251374,
        0.0654754656498403,
        0.04291056767254769,
        0.03246888304261212,
        0.01765456010456301,
        0.010867781283873047,
        0.006244100260015479,
        0.004047563128139043
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Ricoh GR DIGITAL 3 / prf-solomatov-pred-ricoh-gr-digital-3-c0b6b5958be2@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Ricoh GR DIGITAL 3 / prf-solomatov-pred-ricoh-gr-digital-3-c0b6b5958be2@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26866862 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26866862; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.044812725058847584,
        0.11273197070800452,
        0.266317555060952,
        0.44878627805509996,
        0.5718574056024853,
        0.6559325759740754,
        0.717493282244871,
        0.7286734118781717,
        0.6957760828190503,
        0.6074779406690666,
        0.4849696998480879,
        0.3636057683253072,
        0.25197613327525925,
        0.1702810324480767,
        0.12353642193122516,
        0.08662084168966215,
        0.06424962096429422,
        0.05530262521912681,
        0.0553368383698848,
        0.03874944159835265,
        0.013375286626328002,
        0.001124437420343321,
        0.000297115405587746,
        0.00025348334316080526,
        0.004769644478763466,
        0.008545839852826876,
        0.011639654083904551,
        0.008978149737025484,
        0.005021976887364069,
        0.001433771238338143,
        0.0015522250793561228
      ],
      "range": 1
    }
  }
]
