[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Ricoh GR DIGITAL 4 / prf-solomatov-pred-ricoh-gr-digital-4-4f37314ae3f2@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Ricoh GR DIGITAL 4 / prf-solomatov-pred-ricoh-gr-digital-4-4f37314ae3f2@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000534520943396 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2832961; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.012963161379560115,
        0.02216603648198785,
        0.032327937262881655,
        0.009020243073310683,
        0.03408022768724699,
        0.04782195323001074,
        0.059122176024676475,
        0.06388353071709417,
        0.07510642722108306,
        0.07200748760100568,
        0.06287029613185639,
        0.059278636207771275,
        0.06492890151655133,
        0.060366979990194,
        0.05205346050246316,
        0.05841525001258722,
        0.09298138609593083,
        0.23176181474299873,
        0.4328797836707199,
        0.5306517193225494,
        0.5004346165254894,
        0.44460261617831925,
        0.37312605990920866,
        0.3088541401208113,
        0.24670038378131573,
        0.19233783310112637,
        0.14122203117750887,
        0.09133582890623268,
        0.04994195166242297,
        0.019898991176380117,
        0.013666523168817763
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Ricoh GR DIGITAL 4 / prf-solomatov-pred-ricoh-gr-digital-4-4f37314ae3f2@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Ricoh GR DIGITAL 4 / prf-solomatov-pred-ricoh-gr-digital-4-4f37314ae3f2@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000534520943396 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2832961; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.02070684345813444,
        0.03147761622780598,
        0.061532980275172636,
        0.09958145279551087,
        0.13322184007218146,
        0.15345850837104125,
        0.20017949110642466,
        0.3062143017387409,
        0.4243464457329275,
        0.5455313629485913,
        0.6960162077769514,
        0.8673448367550529,
        0.9748916416427901,
        1,
        0.9627703690264029,
        0.8809297480621865,
        0.768147570938776,
        0.6186085543612955,
        0.456375298641172,
        0.31065174612567287,
        0.19808207325597965,
        0.11755836812831083,
        0.0758254305016394,
        0.049871670530955994,
        0.02844269983773162,
        0.013576484652793151,
        0.011184957321610808,
        0.0032086787081753135,
        0.00017190604687836796,
        0.003574354597155783,
        0.00006546901028893192
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Ricoh GR DIGITAL 4 / prf-solomatov-pred-ricoh-gr-digital-4-4f37314ae3f2@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Ricoh GR DIGITAL 4 / prf-solomatov-pred-ricoh-gr-digital-4-4f37314ae3f2@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000534520943396 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2832961; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.05901975477248011,
        0.14362221700623312,
        0.331698927796915,
        0.5472898874981845,
        0.696912568606743,
        0.7970808767850238,
        0.8673274665470234,
        0.8827658005551022,
        0.8410363470705504,
        0.7169401980500837,
        0.5462843011252184,
        0.3706460906478568,
        0.21742342281015953,
        0.11106277142537438,
        0.06487096402354678,
        0.03266904903321359,
        0.026925735690375846,
        0.03329713786474863,
        0.04468096594535444,
        0.039304342191552245,
        0.022849142116675804,
        0.00895093513957108,
        0.00004148359739099377,
        0.000848699220378781,
        0.003574039974208964,
        0.008427754972216758,
        0.008133908404626392,
        0.0074042645597109475,
        0.0040749682669371685,
        0.0008427746129032231,
        0.0030571182186109463
      ],
      "range": 1
    }
  }
]
