[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / RICOH GR LENS A12 28mm F2 / prf-solomatov-pred-ricoh-gr-lens-a12-28mm-f2-a57287fcf88f@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / RICOH GR LENS A12 28mm F2 / prf-solomatov-pred-ricoh-gr-lens-a12-28mm-f2-a57287fcf88f@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27894306 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27894306; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.011664944451387318,
        0.021376687055774033,
        0.02674657222158529,
        0.0076384725255398,
        0.01664941368320832,
        0.032388606477608724,
        0.04188558768947325,
        0.040043717165790034,
        0.04493198360984496,
        0.02324223086962622,
        0.0014053726950582675,
        0.00000693664040252516,
        0.000011351646461467799,
        0.000010315119150123325,
        0.00007649434977876847,
        0.015703792738202556,
        0.07807467230050462,
        0.2568470783965731,
        0.49936029955360783,
        0.6321113348365791,
        0.6157840958652995,
        0.5542295979688471,
        0.47705879472319546,
        0.42191721851764297,
        0.35255661137437866,
        0.28172064936836927,
        0.21759326078949587,
        0.15087030664967968,
        0.08764104043312639,
        0.03775782770863702,
        0.019918640743383252
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / RICOH GR LENS A12 28mm F2 / prf-solomatov-pred-ricoh-gr-lens-a12-28mm-f2-a57287fcf88f@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / RICOH GR LENS A12 28mm F2 / prf-solomatov-pred-ricoh-gr-lens-a12-28mm-f2-a57287fcf88f@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27894306 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27894306; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.016064178115777462,
        0.025667584990284396,
        0.05304407286562354,
        0.0912880822344173,
        0.1311011214976992,
        0.15242059436789715,
        0.18155966310830604,
        0.24906376950191914,
        0.3387847326260779,
        0.4532559799121727,
        0.6038465341277893,
        0.7925074744645018,
        0.9339131792703499,
        1,
        0.9897225261671682,
        0.9327999054717475,
        0.8274647879750082,
        0.679734530767677,
        0.5219841282303277,
        0.3664653424250813,
        0.22965138476648245,
        0.12779744367900744,
        0.08280363024625886,
        0.06327531862595899,
        0.04832320976187757,
        0.032834754877931,
        0.032030280660146196,
        0.01845773112261692,
        0.00962523211726436,
        0.00897259820696023,
        0.00013336121357527232
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / RICOH GR LENS A12 28mm F2 / prf-solomatov-pred-ricoh-gr-lens-a12-28mm-f2-a57287fcf88f@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / RICOH GR LENS A12 28mm F2 / prf-solomatov-pred-ricoh-gr-lens-a12-28mm-f2-a57287fcf88f@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27894306 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27894306; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.050721079061798485,
        0.1229974963349151,
        0.28331463059163403,
        0.45838207984095386,
        0.589857299192172,
        0.7009773966056011,
        0.7916850127047433,
        0.8221009692802538,
        0.7950642328222827,
        0.6695376110092145,
        0.4966620069343184,
        0.31308190639336925,
        0.15980960415362186,
        0.06170576891212135,
        0.043938608832928126,
        0.046354277464368536,
        0.07543796931172979,
        0.07670528888583927,
        0.04658986317852826,
        0.02764044748057184,
        0.035228479962899954,
        0.038507045129568734,
        0.0214885468023474,
        0.000011160584529330107,
        0.00002122191891061925,
        0.000013159284192264901,
        0.0000070208224574578054,
        0.000008134184804597756,
        0.000006140576503319351,
        0.000003791496372055286,
        0.00002426026300851507
      ],
      "range": 1
    }
  }
]
