[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Samsung GX 1L / prf-solomatov-pred-samsung-gx-1l-e01e9b0397a5@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Samsung GX 1L / prf-solomatov-pred-samsung-gx-1l-e01e9b0397a5@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27376512 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27376512; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.005260642042346374,
        0.015339839494527281,
        0.01860405554951632,
        0.0037294615910164167,
        0.013199531773806686,
        0.021265555305219307,
        0.027380842745781495,
        0.025470662588426167,
        0.029030999274122286,
        0.0203959109180892,
        0.008130941954913762,
        0.004482020938240782,
        0.016931382639249294,
        0.025182751549941793,
        0.02864495666942524,
        0.04445391363224067,
        0.09482724826303658,
        0.23988267753028586,
        0.4576392712117599,
        0.5980854317745081,
        0.5921550561298679,
        0.5463479788805821,
        0.4745780251333699,
        0.41286570765479547,
        0.3481412095156608,
        0.2849716939835141,
        0.222009812645234,
        0.15452219406182938,
        0.089859365575863,
        0.03620401678636052,
        0.021849503691339495
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Samsung GX 1L / prf-solomatov-pred-samsung-gx-1l-e01e9b0397a5@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Samsung GX 1L / prf-solomatov-pred-samsung-gx-1l-e01e9b0397a5@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27376512 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27376512; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01554113102501882,
        0.025065042617554788,
        0.05119769457847662,
        0.09092836954539718,
        0.1263204677060394,
        0.14416316804712012,
        0.18123077183828243,
        0.25837698023765776,
        0.35514801885645625,
        0.4725562189953198,
        0.626619709625536,
        0.8149878625881924,
        0.9462257280985978,
        1,
        0.9795205466642355,
        0.9139371735888049,
        0.8065038380345897,
        0.6518100260544514,
        0.47643242499263605,
        0.31859858553200643,
        0.19612960190107492,
        0.10747243111175012,
        0.06693342088283562,
        0.0383395006639268,
        0.018579930854595358,
        0.0016944435799564242,
        0.0000186249621573413,
        0.000033156623458824856,
        5.514170322355163e-7,
        0.0005898596943248286,
        0.00019664058372374102
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Samsung GX 1L / prf-solomatov-pred-samsung-gx-1l-e01e9b0397a5@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Samsung GX 1L / prf-solomatov-pred-samsung-gx-1l-e01e9b0397a5@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27376512 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27376512; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.049817186353031395,
        0.12282604518793339,
        0.2830175005493761,
        0.46194325266856495,
        0.6028396532034468,
        0.7248303582282506,
        0.8255976510082804,
        0.8843778929908969,
        0.892343078621557,
        0.7873831772287135,
        0.6087427061562847,
        0.4016803528513786,
        0.20957928460718445,
        0.06702123703706302,
        0.01695268301527967,
        0.00005790538254106294,
        0.0054810346182888455,
        0.022382982901547138,
        0.03035272353176329,
        0.033839120922343945,
        0.03768329581211807,
        0.038563513861809715,
        0.021822106483104935,
        0.0038662240828926642,
        0.00000836747573978745,
        0.00026003378370480505,
        6.844439130887091e-7,
        0.00003790337863347968,
        0.000014766938169479005,
        0.000008575771084351433,
        0.0008395789792359231
      ],
      "range": 1
    }
  }
]
