[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / SAMSUNG GX20 / prf-solomatov-pred-samsung-gx20-ad68e937166b@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / SAMSUNG GX20 / prf-solomatov-pred-samsung-gx20-ad68e937166b@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.28822201 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28822201; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.008933031172740764,
        0.017146675578315482,
        0.02545516215087113,
        0.014484315753678912,
        0.023854726431197952,
        0.032383047359915366,
        0.030935427172962954,
        0.021634975066616186,
        0.01618799861953638,
        0.0009384512307023326,
        0.0000069402243083378685,
        0.00000254650271157293,
        0.000014226474237689204,
        0.000022370868553723573,
        0.000009506450600354914,
        0.00965166851761252,
        0.06023143756439698,
        0.22292031063137754,
        0.44221300101265687,
        0.5730970372456983,
        0.5601800153985464,
        0.5111681443065366,
        0.4455671515162913,
        0.3920729371084464,
        0.33135563102901133,
        0.26851240472578763,
        0.20787157094629935,
        0.1424827791604118,
        0.08421404388929216,
        0.035597461831592944,
        0.021533155639293478
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / SAMSUNG GX20 / prf-solomatov-pred-samsung-gx20-ad68e937166b@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / SAMSUNG GX20 / prf-solomatov-pred-samsung-gx20-ad68e937166b@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.28822201 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28822201; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01374595472427661,
        0.022164120637421136,
        0.045142756446671095,
        0.07792630757102832,
        0.10503249214034695,
        0.11330890378566162,
        0.13484046551476067,
        0.20050028795510794,
        0.2954758035307575,
        0.4220853223527239,
        0.5855015375126973,
        0.7853293022278209,
        0.9332524604904394,
        1,
        0.9902498424738625,
        0.9288440532352127,
        0.8238359728321929,
        0.6859019545384477,
        0.5380319844414381,
        0.38817614935098127,
        0.25438942015566407,
        0.15472642078930754,
        0.10985941011236444,
        0.08930676737699526,
        0.06771167476071659,
        0.047885596939664675,
        0.043973282956426545,
        0.024836938372610754,
        0.013278826277007784,
        0.012498976049747208,
        0.0006819000047914454
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / SAMSUNG GX20 / prf-solomatov-pred-samsung-gx20-ad68e937166b@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / SAMSUNG GX20 / prf-solomatov-pred-samsung-gx20-ad68e937166b@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.28822201 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28822201; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.044749788539744075,
        0.11383015474772382,
        0.2695512046425601,
        0.45186514381743437,
        0.5897963864730525,
        0.7016060293244086,
        0.7839764562047152,
        0.7936729398285718,
        0.7382650964095352,
        0.5908149762747127,
        0.41211207291212776,
        0.2403386680982483,
        0.11513164452638437,
        0.046211262630497935,
        0.04292852235677629,
        0.05480394783174263,
        0.07945224238773438,
        0.07691252309287552,
        0.05011325123990358,
        0.033110091071809546,
        0.032116832437606,
        0.026634273003647433,
        0.011444577740610442,
        6.710576336623286e-7,
        0.00003426339993951191,
        0.00001346909106629296,
        0.000022860911975459476,
        0.000008726910203700267,
        0.00004159010271283585,
        0.00004138695549309368,
        0.0011080659662320725
      ],
      "range": 1
    }
  }
]
