    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Samsung NX3000 / prf-solomatov-pred-samsung-nx3000-a58ecd85e0a5@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Samsung NX3000 / prf-solomatov-pred-samsung-nx3000-a58ecd85e0a5@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000529795433962 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28079158; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.016021466883016932,
        0.025544728437143966,
        0.031971064157435274,
        0.006724451538372423,
        0.016763501573593548,
        0.030494206018887353,
        0.044837334742079495,
        0.050117067673543764,
        0.0665436557962315,
        0.057358792814316197,
        0.04354513557707108,
        0.0327087697474935,
        0.030456330813053583,
        0.01504638208880765,
        0.0001104541068688213,
        0.00013315632793935956,
        0.04950723517319959,
        0.2373296036368502,
        0.48623884649788024,
        0.5954671227580548,
        0.5685549503775482,
        0.5092324302905543,
        0.4305648172305617,
        0.36340171901572993,
        0.3006677007551295,
        0.23936922620959372,
        0.18225337816451445,
        0.12059854729900035,
        0.06922458512592487,
        0.028224569083681525,
        0.018101905996306178
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Samsung NX3000 / prf-solomatov-pred-samsung-nx3000-a58ecd85e0a5@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Samsung NX3000 / prf-solomatov-pred-samsung-nx3000-a58ecd85e0a5@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000529795433962 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28079158; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.021753361790620648,
        0.03225244261068012,
        0.06356607121705206,
        0.1013990496041128,
        0.13980095777153226,
        0.16025530505975683,
        0.2005944052880788,
        0.29649761971631405,
        0.4135013065859501,
        0.5413036536325815,
        0.6901068536314373,
        0.8603984618392466,
        0.9711399650669998,
        1,
        0.9651955659174788,
        0.8895004420910861,
        0.7817465785985667,
        0.6373513301842735,
        0.48683946869307715,
        0.34763464151680507,
        0.2349901968807849,
        0.15240032266438552,
        0.10724705491525066,
        0.07551778219614841,
        0.051309447373297304,
        0.03182388259976698,
        0.024096636287162087,
        0.01253661858485396,
        0.0061402961856871175,
        0.006190944094239021,
        0.0005241485609056674
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Samsung NX3000 / prf-solomatov-pred-samsung-nx3000-a58ecd85e0a5@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Samsung NX3000 / prf-solomatov-pred-samsung-nx3000-a58ecd85e0a5@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000529795433962 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28079158; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06200058625333423,
        0.14804437546724505,
        0.33975695035001374,
        0.5576467419978971,
        0.6998834298767402,
        0.7899933862372622,
        0.8484102367655227,
        0.8368080119417657,
        0.759970451215097,
        0.6175600022461863,
        0.446700414592204,
        0.2887698556331634,
        0.1673750159898231,
        0.09312340847257598,
        0.07289564802899426,
        0.06344511593066482,
        0.06957248319961325,
        0.06710714621156051,
        0.05253841767742761,
        0.03816623739819732,
        0.027440188674223542,
        0.01716940547207268,
        0.00796064411443419,
        0.0000021135159711302205,
        0.000005438904108609667,
        0.00004328215424737123,
        0.00000587826828494622,
        0.00005393968722281487,
        0.000014143153113150793,
        0.0000074082397518028716,
        0.0005652180244965221
      ],
      "range": 1
    }
  }
]