[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Samsung WB2000 / prf-solomatov-pred-samsung-wb2000-5bf4ae67149a@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Samsung WB2000 / prf-solomatov-pred-samsung-wb2000-5bf4ae67149a@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26535782 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26535782; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01271562149553384,
        0.024312091876546166,
        0.026944684351115033,
        0.0003731974207505925,
        0.011887299948424357,
        0.03168468146143196,
        0.05884764579389444,
        0.08019547718623855,
        0.11303464506906183,
        0.10980231146005043,
        0.09219982663408977,
        0.07111617437918355,
        0.0507093233581735,
        0.014838332256422665,
        0.0000790310984616922,
        0.005120595654576903,
        0.007373276204937167,
        0.22784087162006378,
        0.5720727958949918,
        0.756307690498814,
        0.7344956331040102,
        0.6602228643572666,
        0.5683836263050397,
        0.49242818621286527,
        0.4233790999639656,
        0.3481069824887768,
        0.2782190289323299,
        0.19108097134653879,
        0.11044296716034221,
        0.040779371039451555,
        0.029852110633106645
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Samsung WB2000 / prf-solomatov-pred-samsung-wb2000-5bf4ae67149a@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Samsung WB2000 / prf-solomatov-pred-samsung-wb2000-5bf4ae67149a@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26535782 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26535782; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.0171335745824261,
        0.029736071090725718,
        0.06021588133336338,
        0.09892269238570019,
        0.14028567162633457,
        0.17543926159779274,
        0.2296934757754642,
        0.3250413724381667,
        0.4443923680108617,
        0.5605855519916465,
        0.6961196771966245,
        0.8543759140017052,
        0.9644112240596489,
        1,
        0.9842751195348227,
        0.9244965910558053,
        0.8358915897032919,
        0.7006426643088942,
        0.542775147911601,
        0.4004582190191342,
        0.28786523042735274,
        0.20085367373006002,
        0.14654771809626715,
        0.10023526346425365,
        0.06333186638328578,
        0.03469010636279722,
        0.019755242185815362,
        0.005819217613409697,
        0.0014730142492126292,
        0.005324534999571522,
        0.0005175169512622615
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Samsung WB2000 / prf-solomatov-pred-samsung-wb2000-5bf4ae67149a@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Samsung WB2000 / prf-solomatov-pred-samsung-wb2000-5bf4ae67149a@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26535782 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26535782; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04657429918590678,
        0.11573459564899953,
        0.27199341628597945,
        0.460305206004481,
        0.5860849700981113,
        0.6729766245441721,
        0.7413628511117554,
        0.7598562574865891,
        0.7296808513123901,
        0.6406105913893926,
        0.511506425550225,
        0.3822533664167123,
        0.2626075236825506,
        0.17533272620343351,
        0.1285303519602324,
        0.09063204167112918,
        0.06997070973826963,
        0.06624779326269714,
        0.07331031736694249,
        0.05411751950630284,
        0.021124674222904,
        0.0010773645185960601,
        0.0003009873611412695,
        0.00006038915679967525,
        0.001382557257969635,
        0.008019241716712927,
        0.013194159116923706,
        0.010603784731122676,
        0.007226299191031943,
        0.0012418493640021613,
        0.001777739770397571
      ],
      "range": 1
    }
  }
]
