[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / SIGMA fp L / prf-solomatov-pred-sigma-fp-l-1b6a373c6cc5@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / SIGMA fp L / prf-solomatov-pred-sigma-fp-l-1b6a373c6cc5@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000494057679245 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26185057; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01547133830947933,
        0.029230691904109145,
        0.03163111975694854,
        0.0003865557038709093,
        0.0029017503536116385,
        0.0266629079919725,
        0.060134472297792146,
        0.09405842082521712,
        0.13979427990170118,
        0.14267866436890603,
        0.12337482557322672,
        0.09995430936947335,
        0.07549615239891032,
        0.025751744592345166,
        0.000013301313940378426,
        0.00008246011067235096,
        0.0001302624221898772,
        0.20331205936110408,
        0.5568252198454123,
        0.7043994330462883,
        0.6509054445314618,
        0.5756836628077671,
        0.4909630488623659,
        0.41936199876402175,
        0.35982254950791204,
        0.30360388487102513,
        0.24408233406950497,
        0.16828892820863212,
        0.09321015158962384,
        0.038395955499861356,
        0.03372995701872473
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / SIGMA fp L / prf-solomatov-pred-sigma-fp-l-1b6a373c6cc5@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / SIGMA fp L / prf-solomatov-pred-sigma-fp-l-1b6a373c6cc5@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000494057679245 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26185057; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.024351296428340788,
        0.04042510618770459,
        0.07796062455082864,
        0.1259931461655206,
        0.17568398665488694,
        0.2223802877767694,
        0.28731639144251325,
        0.3959096700303437,
        0.5275410107948209,
        0.6456743840970216,
        0.7712747640763202,
        0.9118333616390296,
        0.9920977647377572,
        1,
        0.9589864696636088,
        0.8835341594739596,
        0.7833545306284528,
        0.6488005869483955,
        0.5008103654506935,
        0.36982246161572746,
        0.26614963972263517,
        0.18923049064229866,
        0.13779831910706097,
        0.0918655606843683,
        0.05856500850609184,
        0.03402652224951752,
        0.020961474151251436,
        0.008650309408353516,
        0.005360983365436249,
        0.004981215614027828,
        0.0029475014263724095
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / SIGMA fp L / prf-solomatov-pred-sigma-fp-l-1b6a373c6cc5@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / SIGMA fp L / prf-solomatov-pred-sigma-fp-l-1b6a373c6cc5@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000494057679245 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26185057; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.062316904064787786,
        0.14623624337700247,
        0.33331070683339953,
        0.5571157253259297,
        0.697278127854649,
        0.7794842014071017,
        0.8363759412726187,
        0.837670649413811,
        0.7958377041468091,
        0.698070356754719,
        0.5613334063011587,
        0.43074953914723635,
        0.30710413018563043,
        0.21241415285061246,
        0.15383883795787576,
        0.10283203091400912,
        0.0658178754257765,
        0.05681987329844772,
        0.07101242619354263,
        0.04933444421749034,
        0.006132963404789736,
        0.000010377100247496494,
        0.00001710101034514308,
        0.000042298419006627044,
        0.00660158623580617,
        0.021366684306302574,
        0.029241558776569903,
        0.02358194052113073,
        0.014459353050998873,
        0.0063235076944949875,
        0.00774493954428174
      ],
      "range": 1
    }
  }
]
