[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony DSC HX95 / prf-solomatov-pred-sony-dsc-hx95-d3b9510b35d8@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony DSC HX95 / prf-solomatov-pred-sony-dsc-hx95-d3b9510b35d8@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27385345 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27385345; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.013483015824704783,
        0.02191842753852471,
        0.018905062543488133,
        0.0013066499618682912,
        0.0009433111030735601,
        0.0002783714063123908,
        0.0028395791982901803,
        0.03025006257909112,
        0.07205167581419916,
        0.07102878565159577,
        0.06009579211070739,
        0.04918162250649025,
        0.04073592280834877,
        0.008852591778558933,
        0.004164508425948258,
        0.005908093179034261,
        0.00456199657152393,
        0.2420906875556981,
        0.613709595405864,
        0.7843321674421119,
        0.7525248997228262,
        0.6825498090310712,
        0.5890717462204694,
        0.5178037012131854,
        0.448660095390436,
        0.3755248655804775,
        0.3040978304271865,
        0.21132193149292075,
        0.11789301905818605,
        0.04700018568325504,
        0.031428654632614635
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony DSC HX95 / prf-solomatov-pred-sony-dsc-hx95-d3b9510b35d8@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony DSC HX95 / prf-solomatov-pred-sony-dsc-hx95-d3b9510b35d8@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27385345 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27385345; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.0178138150167544,
        0.028068877715435023,
        0.05303958011118721,
        0.08442156562205078,
        0.11884464847895836,
        0.14331550688881223,
        0.18582496221975658,
        0.2716281646260071,
        0.3850734215690911,
        0.5084822557466411,
        0.6565461563474917,
        0.8300855439286962,
        0.9532583942250864,
        1,
        0.9845112413226856,
        0.9259343637993241,
        0.8304866343659355,
        0.6979281802000303,
        0.5533184993652628,
        0.4118846412196012,
        0.2971013876217371,
        0.20622714813342682,
        0.15716186887548797,
        0.11847177021140323,
        0.08826023188679931,
        0.05866378532021416,
        0.04532426741383028,
        0.025529013784562512,
        0.01670259768500269,
        0.011208842904845638,
        0.005244487516954779
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Sony DSC HX95 / prf-solomatov-pred-sony-dsc-hx95-d3b9510b35d8@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Sony DSC HX95 / prf-solomatov-pred-sony-dsc-hx95-d3b9510b35d8@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27385345 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27385345; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.046800447465606146,
        0.11413234341214251,
        0.27105088506279545,
        0.46006643334235886,
        0.5771248454237111,
        0.6460286331977925,
        0.6934312494511207,
        0.6763902006711985,
        0.6014426694277542,
        0.4876427885060422,
        0.3525185605658793,
        0.23634531535023567,
        0.15121055805577763,
        0.10380735024517676,
        0.09619916418799909,
        0.09734715410742498,
        0.10742337553169405,
        0.10915622205964541,
        0.09601658113125834,
        0.0782720100842257,
        0.06342240713052912,
        0.0474462855954526,
        0.02715676212952585,
        0.007324820264269082,
        0.000014779308787236385,
        0.000014424761126799754,
        0.000007627336445825313,
        0.000005829489458686754,
        0.000006334443842135273,
        0.00001893675467663453,
        0.000005238918845097624
      ],
      "range": 1
    }
  }
]
